Design codes · rule packs
Check a design against the code that applies to it
Plotlay checks a drawn house and site against the residential rules people most often ask about: setbacks, site coverage, height, building envelopes, private open space and its winter sun, landscaping and permeable area, garage width, window distances to the boundary, fences, sheds, granny flats, car parking, room sizes, stairs and door widths. Pick the codes for your site, enter the few facts a drawing can’t hold, and every rule comes back PASS, WARN, FAIL or UNKNOWN, with its clause and a link to the source.
Codes that come with Plotlay
50 packs, grouped by region as they are in the app. Every pack is partial: it measures what a drawing can show, and lists the other items it knows about as checks to make by hand, with the figures in the note. Each pack in the app says how many of each it has.
Australia
| Where | Packs |
|---|---|
| South Australia | Planning and Design Code (General Neighbourhood Zone, built in); detached dwellings in the General, Suburban, Housing Diversity, Hills, Established and Master Planned Neighbourhood Zones |
| New South Wales | Housing Code; Low Rise Housing Diversity Code (dual occupancies, manor houses, terraces); secondary dwellings (granny flats); exempt development (sheds, decks, carports, fences) |
| Victoria | ResCode (Clauses 54 and 55) and the Building Regulations 2018 siting rules; small second dwellings |
| Queensland | Queensland Housing Code (from 1 September 2026) and the 2010 QDC MP 1.1 and MP 1.2 for councils still in transition |
| Western Australia | Residential Design Codes Volume 1 (Parts B, C and D), by R-Code |
| Tasmania | Tasmanian Planning Scheme, General Residential Zone and exemptions |
| ACT | Territory Plan 2023, the 2026 residential technical specifications (guidance) and exempt development |
| Northern Territory | NT Planning Scheme 2020, single dwellings in Zones LR and LMR |
| Australia | National Construction Code housing notes (NCC 2025 and 2022); Livable Housing Design, with each state’s start date (both indicative) |
New Zealand
| Where | Packs |
|---|---|
| New Zealand | Building Act Schedule 1 exemptions and granny flats; Medium Density Residential Standards (with the Planning Act 2026 changes); Building Code notes and D1 accessible routes (indicative); Auckland, Wellington, Christchurch and Hamilton residential zones; a district plan template. Christchurch’s figures come from the Council’s 2022 printed plan and are not yet verified against the current ePlan. |
Europe
There is no single European building code: building rules are national. These are national codes whose official text is free to read. All are indicative.
| Where | Pack | Checks | Source |
|---|---|---|---|
| France | Accessibility of new dwellings: door and hall widths, stairs inside a dwelling, the turning space in a bathroom; minimum sizes as hand checks | 7 measured, 7 by hand | Arrêté du 24 décembre 2015 (as amended), Code de la construction et de l’habitation, on Légifrance |
| Spain | Stairs inside a dwelling and in common areas, guards, wheelchair accessible dwellings | 12 measured, 6 by hand | Código Técnico de la Edificación, DB SUA (2022 consolidated text), codigotecnico.org |
| Germany | Habitable room height, window sills and guards from the model building code. Each Länder code (Landesbauordnung) differs, and stair sizes are in DIN 18065, which is sold, so they are not included | 3 measured, 4 by hand | Musterbauordnung (2002, amended 2024), Bauministerkonferenz |
UK and Ireland
| Where | Packs |
|---|---|
| England | Householder permitted development; the nationally described space standard; Approved Document M Volume 1 accessible homes; Approved Documents K, B and F for new homes (stair rise, going, pitch and guarding, escape windows, purge ventilation); Approved Document M Volume 2 for buildings other than dwellings (door and corridor widths, accessible WCs, stairs and external steps) |
| Scotland | Householder permitted development |
| Wales | Householder permitted development |
| Ireland | Exempted development, with the July 2026 changes; the Technical Guidance Documents for dwellings (TGD K stairs and guarding, TGD B escape windows, TGD M access, TGD F ventilation); TGD M 2022 for buildings other than dwellings; the 2025 Planning Design Standards for Apartments (floor areas, room widths, ceiling heights) |
Americas
| Where | Packs |
|---|---|
| United States | International Residential Code notes (houses); International Building Code notes (other buildings: ceiling heights, room sizes, egress doors, corridors, stairs, guards, escape openings); the 2010 ADA Standards (doors, accessible routes, toilet rooms, stairs) and a shorter ADA basics pack; Portland, Seattle and Austin single-family zones; a zoning template. All indicative. Figures show in feet and inches as well |
| Canada | National Building Code 2025: Part 9 housing; Section 3.8 accessibility (barrier-free paths, doors, washrooms); Part 3 exits (stairs, exit doors, corridors, guards). All indicative |
Asia
| Where | Packs |
|---|---|
| Singapore | URA landed housing guidelines (indicative) |
What is not included, and why
- An international accessibility pack. ISO 21542:2021 is the international standard, but it is sold, and its free previews stop before the requirements. Plotlay does not put a figure in a pack without reading it in the source.
- A European accessibility pack. EN 17210:2021 is also sold, and it states what a building must do in words, not figures, by design; the figures sit in a separate technical report (CEN/TR 17621), which is sold too. The European Accessibility Act sets no figures for buildings.
- The Eurocodes. They are structural design standards: a floor plan can’t show whether a beam is big enough.
- Ramps, handrails, headroom, landings and the gaps in a balustrade in every pack: the drawing doesn’t hold them yet, so they are hand checks with the figures in the note.
US codes in feet and inches. US codes state their figures in inches and feet, with a rounded metric figure beside them. Plotlay shows both (“at least 815 mm (32 in)”) and tests against the inch figure, so a door exactly 32 in clear passes. Any project drawn in feet and inches sees feet and inches on every pack.
Checked against the source. Every built-in figure is checked against the official source and dated. In October 2026 we checked all 800 rules in the first 38 packs and made 167 corrections; the 12 packs added on 29 October were read against their official sources the same day. A pack check runs with every release: each figure cited, units consistent, and a passing and a failing test case for every measured rule.
Plotlay suggests the codes from the site’s address, or from where the project sits on the map (a city’s or council’s own code only when the address names it). A suggestion is only a suggestion: nothing is switched on until you choose. Where a code depends on a zone, a density or a height you know and the drawing doesn’t, it asks for it, and reports UNKNOWN until you enter it. It never guesses a number. Every pack says what it covers and what it leaves out, the version it follows, when that took effect and when we last checked it against the source.
Your own rules, as a template
Not every rule is a code. An estate’s design guidelines, body corporate by-laws, a client brief, a council’s local policy or your firm’s standards can be a template of checks: “front setback at least 6.0 m, give or take 0.2”, “bedrooms at least 9.5 m²”, “doors 820 mm clear”. Start blank, from a starter (estate guidelines, body corporate, client brief, small lot or townhouse, granny flat, deck or pergola, shed or carport, fences, pool fencing for Australia, New Zealand or the US, an accessible bathroom, a kitchen work triangle, accessibility, office fit-out), or copy a built-in code and change its numbers. Starters with figures cite where each comes from and are marked indicative. Save it to your library or your team’s and use it on every project. Reports say when a pack is your own template rather than an official code.
Your own standards, from a spreadsheet
Most studios already keep their standards in a spreadsheet: a minimum hallway width, a vanity height of 850 ± 20 mm, a shower recess size, a door clear width. In Design codes, Download a template gives you a file to write them in:
- Excel: a Rules sheet with a dropdown on every column that takes a set of values and a note saying what each column takes, an About the pack sheet for its name, version and author, Instructions with worked examples, and the Lists of measures and units.
- CSV: the same columns with example rows, for any spreadsheet.
- JSON and YAML: the pack as Plotlay keeps it, the YAML with every field explained.
A figure can be a limit (at least 1000 mm), a minimum and a maximum, or a target with a plus or minus. Lengths in m or cm are converted to millimetres. Fit-out is measured too: the top of a vanity, the size of a shower recess, the height of a bench, from what you place and the heights you set.
Import a pack takes the file dropped in, or a table pasted from Excel, Numbers or Word, and shows every rule before anything is added, with any problem marked on its row in plain words (“Row 7: Unit: ‘mm²’ isn’t a length; this check measures a length”). A spreadsheet you already have usually reads as it is: headers such as Min, Max, Tolerance, Clause and Notes are understood, and a CSV saved in Europe, with semicolons and decimal commas, works. Plotlay reads tables and pack files, not rules written in a PDF or Word document: for those, an AI agent connected to Plotlay can read the document and build the pack for you to review.
Export gives any pack as a file in each format, to change and import again: it comes back exactly as it went out. A built-in code exports as your own copy, a template with its own name, so you can start from the code and set your own figures while every other project keeps the published one.
The same version, every time
A project keeps the version of each code it was checked against. When a code changes, Plotlay tells you a newer version is there; your project moves to it only when you choose. Every compliance report lists the codes and versions it used.
What Plotlay measures
Measured from the drawing, not typed in: setbacks to the outside face of the walls, site coverage, landscaped, deep soil and permeable area (counting only parts as wide as the code asks), private open space and its narrowest part, the hours of winter sun on it from the house, sheds and fences on the site, a building envelope from the side and rear boundaries (including planes that change with the way a boundary faces), how far each window looks to the boundary, garage doors as a share of the frontage, a granny flat’s area and setbacks, room areas and widths, a wheelchair turning circle clear of fittings, the kitchen work triangle, and stair risers and goings once you set them. Heights you know and the drawing doesn’t (the building height, a zone, an R-Code) are entered once per project.
Councils and consultants: publish your rules
A rule pack is a short file in Excel, CSV, JSON or YAML: each rule with its clause, the figure, and a link to your document. Anyone can import it into a project. Read the pack format.
With an AI agent
An AI agent connected to Plotlay can read a council guideline, a covenant or your studio’s standards and build the pack: each rule with its clause and source. It can also start from a template, export a pack and import a spreadsheet, as the app does. Rules an agent enters are marked for review until a person confirms them, and reports say “Includes rules entered by an AI agent and not yet reviewed.” Connect an agent.
Every pack, with its rules and sources
Each page lists the rules the pack checks, the clause and published source for each, and what it leaves to a hand check. The templates for your own figures are in the app.
Australia
- Livable Housing Design, Class 1a houses (INDICATIVE) 15 rules
- NCC housing notes, Class 1 and 10 (INDICATIVE) 31 rules
- NSW Housing Code (complying development) 39 rules
- NSW Low Rise Housing Diversity Code (complying development) 42 rules
- NSW exempt development: sheds, decks, carports and fences 19 rules
- NSW secondary dwellings (granny flats): complying development 25 rules
- Victoria ResCode (Clauses 54 and 55) and Building Regulations siting 34 rules
- Victoria small second dwelling (granny flat up to 60 m²) 8 rules
- Queensland Housing Code Chapter 1 (QDC MP 1.1): houses on lots under 450 m² 34 rules
- Queensland Housing Code Chapter 2 (QDC MP 1.2): houses on lots 450 m² and over 29 rules
- WA Residential Design Codes Volume 1: single houses (deemed-to-comply) 43 rules
- SA Planning and Design Code: detached dwellings in neighbourhood zones 47 rules
- Tasmanian Planning Scheme: General Residential Zone (dwellings) 22 rules
- ACT single dwelling housing: Territory Plan 2023, technical specifications and exempt development 35 rules
- NT Planning Scheme 2020: dwelling-single in Zones LR and LMR 17 rules
New Zealand
- Auckland Unitary Plan: Single House and Mixed Housing Suburban zones 16 rules
- Christchurch District Plan: Residential Suburban Zone 14 rules
- Hamilton City District Plan: General Residential Zone 17 rules
- NZ Building Code D1 accessible routes (INDICATIVE) 6 rules
- NZ Building Code: stairs, barriers, light and ventilation (INDICATIVE) 16 rules
- NZ Medium Density Residential Standards (RMA Schedule 3A) 13 rules
- NZ exempt building work (Building Act 2004 Schedules 1 and 1A) 24 rules
- Wellington City District Plan: Medium Density Residential Zone 17 rules
United Kingdom
- Approved Document M Volume 1, accessible dwellings (England) 13 rules
- England Approved Document M Volume 2, buildings other than dwellings: doors, corridors, accessible WCs, stairs (INDICATIVE) 22 rules
- England Approved Documents K, B and F for new dwellings: stairs, guarding, escape windows (INDICATIVE) 17 rules
- England householder permitted development (GPDO 2015 Sch 2 Parts 1 and 2) 21 rules
- England nationally described space standard (new homes) 9 rules
- Scotland householder permitted development (GPDO (Scotland) 1992 Sch 1 Part 1) 17 rules
- Wales householder permitted development (GPDO 1995 Sch 2 Parts 1 and 2, Wales) 21 rules
Ireland
- Ireland Building Regulations TGDs for dwellings: stairs, escape windows, access (INDICATIVE) 25 rules
- Ireland Planning Design Standards for Apartments 2025: floor areas, room widths, ceiling heights (INDICATIVE) 11 rules
- Ireland TGD M 2022: access in buildings other than dwellings (INDICATIVE) 14 rules
- Ireland exempted development for houses (PDR 2001 Sch 2 Part 1) 21 rules
United States
- 2010 ADA Standards for Accessible Design: doors, routes, toilet rooms, stairs (INDICATIVE) 21 rules
- Accessibility basics: 2010 ADA Standards (INDICATIVE) 10 rules
- Austin, Texas SF-3 family residence district: setbacks, height, coverage, setback planes, fences 11 rules
- Portland, Oregon single-dwelling zones (RF to R2.5): setbacks, height, coverage, outdoor area, accessory buildings, fences, ADUs 17 rules
- Seattle Neighborhood Residential (NR) zones: setbacks, height, lot coverage, fences, ADUs 16 rules
- US International Building Code: egress, stairs, guards, room sizes (INDICATIVE) 27 rules
- US International Residential Code: room sizes, egress, stairs, guards (INDICATIVE) 20 rules
Canada
- National Building Code of Canada 2025, Part 3 exits: stairs, exit doors, corridors, guards (INDICATIVE) 15 rules
- National Building Code of Canada 2025, Part 9 housing: ceiling heights, doors, bedroom windows, stairs, guards (INDICATIVE) 23 rules
- National Building Code of Canada 2025, Section 3.8 accessibility: barrier-free paths, doors, washrooms (INDICATIVE) 23 rules
Europe
- Germany Musterbauordnung: room height, window sills and guards (INDICATIVE) 7 rules
- Spain CTE DB SUA: stairs, guards and wheelchair accessible dwellings (INDICATIVE) 18 rules
- France new dwellings: accessibility (arrêté du 24 décembre 2015) and minimum sizes (INDICATIVE) 14 rules