Plotlay Open the app →

Design codes · Wales

Wales householder permitted development (GPDO 1995 Sch 2 Parts 1 and 2, Wales)

Covers householder permitted development for a house in Wales: extensions (Class A), roof extensions and alterations (Classes B and C), porches (Class D), outbuildings (Class E), hard surfaces (Class F) and gates, fences and walls (Part 2 Class A). Measures outbuilding position and heights, fence heights and extension eaves near a boundary; most extension limits are hand checks because they depend on the original house. Does not cover flats, listed buildings, Article 4 directions, microgeneration, chimneys and antennas (Classes G and H) or building regulations.

21rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
21 December 2020instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

The Town and Country Planning (General Permitted Development) Order 1995 (S.I. 1995/418) as it applies in Wales, Schedule 2 Part 1 (Classes A to F) as substituted by S.I. 2013/1776 (W. 177), and Part 2 Class A

Revised text on legislation.gov.uk, shown as up to date with all known changes (seen 2026-10-14). Part 1 as substituted for Wales by the Town and Country Planning (General Permitted Development) (Amendment) (Wales) Order 2013 (S.I. 2013/1776) from 30 September 2013; the only later change to Part 1 is to Class H antennas (S.I. 2020/1318, 21 December 2020). Part 2 Class A as made (Part 2 Classes D and E added 2019). Welsh Government technical guidance: Permitted development for householders (version 2, April 2014). Source: legislation.gov.uk: GPDO 1995 Schedule 2 Parts 1 and 2 (Wales); Welsh Government: Permitted development for householders, technical guidance.

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Buildings cover no more than half the gardenSch 2 Pt 1 Class A para A.1(a); Class E para E.1(a)
Extension no higher than the existing roof or eavesSch 2 Pt 1 Class A para A.1(b), (c); A.4, A.5
Extension eaves within 2 m of a side boundarySch 2 Pt 1 Class A para A.1(d)(i)
Extension eaves within 2 m of the rear boundarySch 2 Pt 1 Class A para A.1(d)(i)
Extension height within 2 m of a boundarySch 2 Pt 1 Class A para A.1(d)(ii)
No extension forward of the front, or towards a highway at the sideSch 2 Pt 1 Class A para A.1(e), (f); A.6
Side extensionsSch 2 Pt 1 Class A para A.1(g), (h)
Rear extensionsSch 2 Pt 1 Class A para A.1(i), (j)
Balconies, raised platforms and other excluded worksSch 2 Pt 1 Class A para A.1(k), (l); para I.1
Extra limits on article 1(5) land and World Heritage SitesSch 2 Pt 1 Class A para A.2
Upper floor side windows within 10.5 m of a boundarySch 2 Pt 1 Class A para A.3(b); Class B para B.2(b); Class C para C.2(b)
Loft conversions, dormers and roof lights (Classes B and C)Sch 2 Pt 1 Class B paras B.1, B.2; Class C para C.1
Porches (Class D)Sch 2 Pt 1 Class D para D.1
Outbuilding not forward of the front of the houseSch 2 Pt 1 Class E para E.1(b); E.4
Outbuilding heightSch 2 Pt 1 Class E para E.1(e), (f), (h)
Outbuilding eaves heightSch 2 Pt 1 Class E para E.1(g); E.5
Outbuildings: single storey, use and other limitsSch 2 Pt 1 Class E paras E.1(d), (i) to (m), E.2
Front garden hard surfaces drain to a porous areaSch 2 Pt 1 Class F para F.2
Fence, wall or gate next to a road used by vehiclesSch 2 Pt 2 Class A para A.1(a)
Other fences, walls and gatesSch 2 Pt 2 Class A para A.1(b), (c)
Permitted development rights apply hereGPDO 1995 arts 3, 4; Sch 2 Pt 1

What it does not cover

Reference only. Indicative only: this checks a few measurable limits of householder permitted development in Wales and does not cover every condition. It is not a Lawful Development Certificate. Rights are narrower on article 1(5) land (National Parks, Areas of Outstanding Natural Beauty, conservation areas) and in World Heritage Sites, do not apply to flats or maisonettes, are limited for listed buildings, and can be removed by an Article 4 direction or a planning condition. Measurements are from the original house (as built or as it stood on 1 July 1948). Check with your local planning authority before building.

Check a design against it

Open your project in Plotlay, choose Design codes, pick Wales householder permitted development (GPDO 1995 Sch 2 Parts 1 and 2, Wales) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →

Every design code pack →