Design codes · Canada
National Building Code of Canada 2025, Part 9 housing: ceiling heights, doors, bedroom windows, stairs, guards (INDICATIVE)
Covers a few NBC 2025 Part 9 items for a house: ceiling heights, door sizes, bedroom escape windows, private stair rise, run and width, guards on stairs, and reminders for headroom, guards and window fall protection. Ceiling heights, door and window sizes and stair dimensions are measured; the rest are hand checks. Does not cover structure, fire separations, energy, plumbing, provincial or city amendments, and is not a permit review.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
National Building Code of Canada 2025, Division B, Part 9 (Housing and Small Buildings)
NBC 2025, Sixteenth Edition, First Printing, published by the National Research Council of Canada on 2025-12-22 (DOI 10.4224/26fz-gg26), read in the free PDF from the NRC Publications Archive 2026-10-14. The Part 9 figures used here (Table 9.5.3.1., Table 9.5.5.1., 9.8.2., Tables 9.8.4.1. and 9.8.4.2., 9.8.8., 9.9.10.1.) are the same as in NBC 2020. Provinces and territories adopt the 2025 edition on their own timetables, and many still enforce a code based on NBC 2020. Source: National Building Code of Canada 2025 (NRC Publications Archive, free PDF).
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Ceiling height of rooms and halls: 2.1 m | NBC 2025 Div B 9.5.3.1.(1), Table 9.5.3.1. |
| Secondary suites: lower heights allowed | NBC 2025 Div B 9.5.3.1.(2) to (4) |
| Garage clear height | NBC 2025 Div B 9.5.3.3. |
| No national minimum room areas | NBC 2025 Div B Section 9.5. |
| Hallway width in a dwelling: 860 mm | NBC 2025 Div B 9.5.4.1. |
| Main entrance door: 810 mm wide | NBC 2025 Div B 9.5.5.1.(1), Table 9.5.5.1. |
| Doors in a dwelling: 1980 mm high | NBC 2025 Div B 9.5.5.1., Table 9.5.5.1. |
| Doors in a dwelling: at least 610 mm wide | NBC 2025 Div B 9.5.5.1., Table 9.5.5.1. |
| Bedroom escape window or door | NBC 2025 Div B 9.9.10.1.(1) |
| Bedroom escape window: 0.35 m² opening | NBC 2025 Div B 9.9.10.1.(2)(a) |
| Bedroom escape window: no dimension under 380 mm (width) | NBC 2025 Div B 9.9.10.1.(2)(a) |
| Bedroom escape window: no dimension under 380 mm (height) | NBC 2025 Div B 9.9.10.1.(2)(a) |
| Bedroom escape window sill height (recommendation) | NBC 2025 Div B Note A-9.9.10.1.(1) |
| Window wells at escape windows: 760 mm clearance | NBC 2025 Div B 9.9.10.1.(3) to (5) |
| Private stairs: rise 125 to 200 mm | NBC 2025 Div B 9.8.4.1.(1), Table 9.8.4.1. |
| Private stairs: rectangular tread run 255 to 355 mm | NBC 2025 Div B 9.8.4.2.(1), Table 9.8.4.2. |
| Stair width in a house: 860 mm | NBC 2025 Div B 9.8.2.1.(2) and (4) |
| Headroom over stairs in a house: 1950 mm | NBC 2025 Div B 9.8.2.2.(3) |
| Guards where a drop is more than 600 mm | NBC 2025 Div B 9.8.8.1.(1) |
| Guard on stairs inside a house: 900 mm | NBC 2025 Div B 9.8.8.3.(2) and (4) |
| Guard height: 900 mm or 1070 mm | NBC 2025 Div B 9.8.8.3. |
| Guard openings: 100 mm sphere | NBC 2025 Div B 9.8.8.5. |
| Opening windows: guard or opening limiter | NBC 2025 Div B 9.8.8.1.(4) and (5) |