National Building Code of Canada 2025, Part 9 housing: ceiling heights, doors, bedroom windows, stairs, guards (INDICATIVE)

Covers a few NBC 2025 Part 9 items for a house: ceiling heights, door sizes, bedroom escape windows, private stair rise, run and width, guards on stairs, and reminders for headroom, guards and window fall protection. Ceiling heights, door and window sizes and stair dimensions are measured; the rest are hand checks. Does not cover structure, fire separations, energy, plumbing, provincial or city amendments, and is not a permit review.

23rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
22 December 2025instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

National Building Code of Canada 2025, Division B, Part 9 (Housing and Small Buildings)

NBC 2025, Sixteenth Edition, First Printing, published by the National Research Council of Canada on 2025-12-22 (DOI 10.4224/26fz-gg26), read in the free PDF from the NRC Publications Archive 2026-10-14. The Part 9 figures used here (Table 9.5.3.1., Table 9.5.5.1., 9.8.2., Tables 9.8.4.1. and 9.8.4.2., 9.8.8., 9.9.10.1.) are the same as in NBC 2020. Provinces and territories adopt the 2025 edition on their own timetables, and many still enforce a code based on NBC 2020. Source: National Building Code of Canada 2025 (NRC Publications Archive, free PDF).

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Ceiling height of rooms and halls: 2.1 mNBC 2025 Div B 9.5.3.1.(1), Table 9.5.3.1.
Secondary suites: lower heights allowedNBC 2025 Div B 9.5.3.1.(2) to (4)
Garage clear heightNBC 2025 Div B 9.5.3.3.
No national minimum room areasNBC 2025 Div B Section 9.5.
Hallway width in a dwelling: 860 mmNBC 2025 Div B 9.5.4.1.
Main entrance door: 810 mm wideNBC 2025 Div B 9.5.5.1.(1), Table 9.5.5.1.
Doors in a dwelling: 1980 mm highNBC 2025 Div B 9.5.5.1., Table 9.5.5.1.
Doors in a dwelling: at least 610 mm wideNBC 2025 Div B 9.5.5.1., Table 9.5.5.1.
Bedroom escape window or doorNBC 2025 Div B 9.9.10.1.(1)
Bedroom escape window: 0.35 m² openingNBC 2025 Div B 9.9.10.1.(2)(a)
Bedroom escape window: no dimension under 380 mm (width)NBC 2025 Div B 9.9.10.1.(2)(a)
Bedroom escape window: no dimension under 380 mm (height)NBC 2025 Div B 9.9.10.1.(2)(a)
Bedroom escape window sill height (recommendation)NBC 2025 Div B Note A-9.9.10.1.(1)
Window wells at escape windows: 760 mm clearanceNBC 2025 Div B 9.9.10.1.(3) to (5)
Private stairs: rise 125 to 200 mmNBC 2025 Div B 9.8.4.1.(1), Table 9.8.4.1.
Private stairs: rectangular tread run 255 to 355 mmNBC 2025 Div B 9.8.4.2.(1), Table 9.8.4.2.
Stair width in a house: 860 mmNBC 2025 Div B 9.8.2.1.(2) and (4)
Headroom over stairs in a house: 1950 mmNBC 2025 Div B 9.8.2.2.(3)
Guards where a drop is more than 600 mmNBC 2025 Div B 9.8.8.1.(1)
Guard on stairs inside a house: 900 mmNBC 2025 Div B 9.8.8.3.(2) and (4)
Guard height: 900 mm or 1070 mmNBC 2025 Div B 9.8.8.3.
Guard openings: 100 mm sphereNBC 2025 Div B 9.8.8.5.
Opening windows: guard or opening limiterNBC 2025 Div B 9.8.8.1.(4) and (5)

What it does not cover

INDICATIVE only. The National Building Code is a model code: it has legal force only where a province or territory adopts it, and each adopts a new edition on its own timetable. Ontario, British Columbia, Alberta, Quebec and others publish their own building codes based on it, with changes, and some cities (for example Vancouver) have their own. Check the code and edition your building official enforces. This pack covers a few Part 9 items, not the whole code, and is not a permit review.

Check a design against it

Open your project in Plotlay, choose Design codes, pick National Building Code of Canada 2025, Part 9 housing: ceiling heights, doors, bedroom windows, stairs, guards (INDICATIVE) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →

Other packs for Canada

Every design code pack →