Plotlay Open the app →

Design codes · Canada

National Building Code of Canada 2025, Section 3.8 accessibility: barrier-free paths, doors, washrooms (INDICATIVE)

Covers NBC 2025 Section 3.8 barrier-free design for buildings other than houses: path of travel width, doorway clear width and the universal washroom turning space are measured; ramps, door clear spaces and hardware, controls, washroom, stall, grab bar, lavatory and shower dimensions, counters, seating, and the new adaptable and visitable dwelling unit rules are hand checks. Does not cover signs, lifts, assistive listening, parking counts, provincial accessibility codes or the CSA B651 alternative.

23rules checked on the drawing
2026.10.1pack version, checked 29 October 2026
22 December 2025instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

National Building Code of Canada 2025, Division B, Section 3.8 (Accessibility)

NBC 2025, Sixteenth Edition, First Printing, published by the National Research Council of Canada on 2025-12-22 (DOI 10.4224/26fz-gg26), read in the free PDF from the NRC Publications Archive 2026-10-29. Provinces and territories adopt the 2025 edition on their own timetables, and many still enforce a code based on NBC 2020. Source: National Building Code of Canada 2025 (NRC Publications Archive, free PDF).

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Which buildings must be barrier-freeNBC 2025 Div B 3.8.1.1., 3.8.2.1., 3.8.3.1.(1)
Where the barrier-free path must goNBC 2025 Div B 3.8.2.2. and 3.8.2.3.
Barrier-free path of travel: 1000 mm clearNBC 2025 Div B 3.8.3.2.(1) and (2)
Long paths: passing and turning spacesNBC 2025 Div B 3.8.3.2.(5) and (6)
Path surfaces, slopes and level changesNBC 2025 Div B 3.8.3.2.(3)
Exterior walks: 1600 mm wideNBC 2025 Div B 3.8.3.3.(1)
Ramps: 1 in 12 maximum, landings, handrailsNBC 2025 Div B 3.8.3.5.
Doorways on a barrier-free path: 850 mm clearNBC 2025 Div B 3.8.3.6.(2) and (3), Note A-3.8.3.6.(2)
Clear space beside and in front of doorsNBC 2025 Div B 3.8.3.6.(11), (12) and (14) to (16)
Door thresholds, opening force, closers and hardwareNBC 2025 Div B 3.8.3.6.(4), (5), (8) to (10)
Power door operatorsNBC 2025 Div B 3.8.2.7., 3.8.3.6.(6) and (7)
Controls: 400 mm to 1200 mm above the floorNBC 2025 Div B 3.8.2.6., 3.8.3.8.(1)
Which washrooms must be barrier-freeNBC 2025 Div B 3.8.2.8.
Universal washroom: 1700 mm turning spaceNBC 2025 Div B 3.8.3.13.(1)(j)
Universal washroom fit-outNBC 2025 Div B 3.8.3.13.
Accessible water-closet stall: 1500 by 1500 mmNBC 2025 Div B 3.8.3.12.(1)
Water closet and grab barsNBC 2025 Div B 3.7.2.7., 3.8.3.12.(1)(f) and (g), 3.8.3.14.
Limited-mobility stalls and urinalsNBC 2025 Div B 3.8.3.15.
Lavatory, mirror and dispensersNBC 2025 Div B 3.8.3.16.
Accessible shower: 1500 by 900 mmNBC 2025 Div B 3.8.3.17.(1)
Service counters: 865 mm high sectionNBC 2025 Div B 3.8.2.11., 3.8.3.20.
Wheelchair spaces in fixed seatingNBC 2025 Div B 3.8.2.3.(3) to (6), Table 3.8.2.3., 3.8.3.22.
Adaptable and visitable dwelling units (new in NBC 2025)NBC 2025 Div B 3.8.2.1.(4) and (5), Subsections 3.8.4. and 3.8.5.

What it does not cover

The National Building Code is a model code: it has legal force only where a province or territory adopts it, and each adopts a new edition on its own timetable. Ontario, British Columbia, Alberta, Quebec and others publish their own building codes based on it, with changes, and some cities (for example Vancouver) have their own. Your building official decides compliance with the code and edition they enforce. This pack covers a few Section 3.8 items, not the whole code, and is not a permit review.

Check a design against it

Open your project in Plotlay, choose Design codes, pick National Building Code of Canada 2025, Section 3.8 accessibility: barrier-free paths, doors, washrooms (INDICATIVE) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →

Other packs for Canada