Plotlay Open the app →

Design codes · Spain

Spain CTE DB SUA: stairs, guards and wheelchair accessible dwellings (INDICATIVE)

Checks stairs inside a dwelling and common stairs (rise, going, the 2C + H relation, width), stair guard height and, for a dwelling designed for wheelchair users, door widths, corridor widths and turning circles, from the Spanish DB SUA. Hand checks cover where guards are needed, handrails, ramps, the accessible route in common areas and accessible WCs. Regional accessibility codes and the fire evacuation widths of DB SI are not covered.

18rules checked on the drawing
2026.10.1pack version, checked 29 October 2026
16 June 2022instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

Código Técnico de la Edificación, Documento Básico SUA Seguridad de utilización y accesibilidad (Real Decreto 314/2006)

DB SUA consolidated text of 14 June 2022, with the changes of Real Decreto 450/2022 (BOE 15/06/2022); the stair, guard and accessibility figures used here date from Real Decreto 173/2010. The ministry notes the consolidated text has no legal force of its own: the BOE text does. Read on codigotecnico.org 2026-10-29 Source: Ministerio de Transportes, Movilidad y Agenda Urbana: CTE DB SUA (codigotecnico.org, free PDF).

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Stair inside a dwelling (uso restringido): 0.80 m wideCTE DB SUA, SUA 1, 4.1.1
Stair inside a dwelling: rise 20 cm at mostCTE DB SUA, SUA 1, 4.1.2
Stair inside a dwelling: going 22 cm at leastCTE DB SUA, SUA 1, 4.1.2
Common stair (uso general): going 28 cm at leastCTE DB SUA, SUA 1, 4.2.1(1)
Common stair: rise 13 cm to 18.5 cmCTE DB SUA, SUA 1, 4.2.1(1)
Common stair: 54 cm to 70 cm for two risers plus a goingCTE DB SUA, SUA 1, 4.2.1(1)
Common stair in housing: 1.00 m wideCTE DB SUA, SUA 1, 4.2.2(4), Tabla 4.1
Stair guard: 0.90 m highCTE DB SUA, SUA 1, 3.2.1
Wheelchair accessible dwelling: doors 0.80 m clearCTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas
Wheelchair accessible dwelling: corridors 1.10 m wideCTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas
Wheelchair accessible dwelling: 1.50 m turning circle in bedrooms, living room and kitchenCTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas
Wheelchair accessible dwelling: 1.50 m turning circle in the bathroomCTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas
Where these rules applyCTE DB SUA, SUA 9, 1(2) and 1.2.1; Anejo A, Uso restringido
Guards where the drop is more than 55 cmCTE DB SUA, SUA 1, 3.1, 3.2.1 and 3.2.3
Stair handrails: above 55 cm, 0.90 m to 1.10 m highCTE DB SUA, SUA 1, 4.2.4
Ramps: 12 % at most, 10 / 8 / 6 % on an accessible routeCTE DB SUA, SUA 1, 4.3
Accessible route in common areas: 1.20 m (1.10 m in housing), 1.50 m turningCTE DB SUA, SUA 9, 1.1; Anejo A, Itinerario accesible
Accessible WC in other buildings: 1.50 m turning, 0.80 m transferCTE DB SUA, SUA 9 1.2.6; Anejo A, Servicios higiénicos accesibles

What it does not cover

The project architect and the local council (ayuntamiento) that grants the licence decide compliance; the autonomous community may add its own accessibility rules.

Check a design against it

Open your project in Plotlay, choose Design codes, pick Spain CTE DB SUA: stairs, guards and wheelchair accessible dwellings (INDICATIVE) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →