Design codes · Spain
Spain CTE DB SUA: stairs, guards and wheelchair accessible dwellings (INDICATIVE)
Checks stairs inside a dwelling and common stairs (rise, going, the 2C + H relation, width), stair guard height and, for a dwelling designed for wheelchair users, door widths, corridor widths and turning circles, from the Spanish DB SUA. Hand checks cover where guards are needed, handrails, ramps, the accessible route in common areas and accessible WCs. Regional accessibility codes and the fire evacuation widths of DB SI are not covered.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
Código Técnico de la Edificación, Documento Básico SUA Seguridad de utilización y accesibilidad (Real Decreto 314/2006)
DB SUA consolidated text of 14 June 2022, with the changes of Real Decreto 450/2022 (BOE 15/06/2022); the stair, guard and accessibility figures used here date from Real Decreto 173/2010. The ministry notes the consolidated text has no legal force of its own: the BOE text does. Read on codigotecnico.org 2026-10-29 Source: Ministerio de Transportes, Movilidad y Agenda Urbana: CTE DB SUA (codigotecnico.org, free PDF).
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Stair inside a dwelling (uso restringido): 0.80 m wide | CTE DB SUA, SUA 1, 4.1.1 |
| Stair inside a dwelling: rise 20 cm at most | CTE DB SUA, SUA 1, 4.1.2 |
| Stair inside a dwelling: going 22 cm at least | CTE DB SUA, SUA 1, 4.1.2 |
| Common stair (uso general): going 28 cm at least | CTE DB SUA, SUA 1, 4.2.1(1) |
| Common stair: rise 13 cm to 18.5 cm | CTE DB SUA, SUA 1, 4.2.1(1) |
| Common stair: 54 cm to 70 cm for two risers plus a going | CTE DB SUA, SUA 1, 4.2.1(1) |
| Common stair in housing: 1.00 m wide | CTE DB SUA, SUA 1, 4.2.2(4), Tabla 4.1 |
| Stair guard: 0.90 m high | CTE DB SUA, SUA 1, 3.2.1 |
| Wheelchair accessible dwelling: doors 0.80 m clear | CTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas |
| Wheelchair accessible dwelling: corridors 1.10 m wide | CTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas |
| Wheelchair accessible dwelling: 1.50 m turning circle in bedrooms, living room and kitchen | CTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas |
| Wheelchair accessible dwelling: 1.50 m turning circle in the bathroom | CTE DB SUA, Anejo A, Vivienda accesible para usuarios de silla de ruedas |
| Where these rules apply | CTE DB SUA, SUA 9, 1(2) and 1.2.1; Anejo A, Uso restringido |
| Guards where the drop is more than 55 cm | CTE DB SUA, SUA 1, 3.1, 3.2.1 and 3.2.3 |
| Stair handrails: above 55 cm, 0.90 m to 1.10 m high | CTE DB SUA, SUA 1, 4.2.4 |
| Ramps: 12 % at most, 10 / 8 / 6 % on an accessible route | CTE DB SUA, SUA 1, 4.3 |
| Accessible route in common areas: 1.20 m (1.10 m in housing), 1.50 m turning | CTE DB SUA, SUA 9, 1.1; Anejo A, Itinerario accesible |
| Accessible WC in other buildings: 1.50 m turning, 0.80 m transfer | CTE DB SUA, SUA 9 1.2.6; Anejo A, Servicios higiénicos accesibles |