Plotlay Open the app →

Design codes · Ireland

Ireland exempted development for houses (PDR 2001 Sch 2 Part 1)

Covers the main exempted development classes for houses in Ireland: rear extensions (Class 1), dormers and roof lights (Classes 1B and 1C), sheds and garages (Class 3), rear garden houses (Class 3A), walls and fences (Class 5), hard surfaces (Class 6), porches (Class 7) and bin or bike stores (Class 62), with the July 2026 changes. Measures shed position, area and height, fence heights, private open space and extension window distances to the boundary. Does not cover article 9 restrictions in detail, protected structures, architectural conservation areas, Part 3 rural classes, or building regulations.

21rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
27 July 2026instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

Planning and Development Regulations 2001 (S.I. No. 600 of 2001), Schedule 2 Part 1, as amended

Planning and Development Regulations 2001 to 2026, checked on irishstatutebook.ie 2026-10-14 against the Legislation Directory list of amendments to S.I. No. 600 of 2001. Classes 1 and 3 as substituted by S.I. No. 338/2026 (in operation 27 July 2026); Classes 1A, 1B, 1C, 2A, 3A, 62 and 63 inserted and Class 2(d) substituted by S.I. Nos. 339 to 344/2026 (all 27 July 2026). Class 6 as substituted by S.I. No. 454/2011 (8 September 2011). Classes 5 and 7 as made in 2001: no later instrument amends them. No revised (consolidated) text of the Regulations is published by the Law Reform Commission. Source: Irish Statute Book: S.I. No. 600 of 2001 and S.I. Nos. 338 to 344 of 2026.

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Rear extension floor areaSch 2 Pt 1 Class 1 conditions 1 and 2 (as substituted by S.I. 338/2026)
Upper floor extension 2 m from party boundarySch 2 Pt 1 Class 1 condition 3
Rear extension wall and roof heightSch 2 Pt 1 Class 1 condition 4
At least 25 square metres of private open space leftSch 2 Pt 1 Class 1 condition 5; Class 3 condition 3; Class 3A condition 9
Upper floor extension windows 8 m from the boundarySch 2 Pt 1 Class 1 condition 6(b) and (c) (as substituted by S.I. 338/2026)
Ground floor extension windows 1 m from the boundarySch 2 Pt 1 Class 1 condition 6(a) (as substituted by S.I. 338/2026)
Extension roof not a balcony or terraceSch 2 Pt 1 Class 1 conditions 7 and 8
Dormers and front roof lightsSch 2 Pt 1 Classes 1B and 1C (inserted by S.I. 344/2026)
Shed or garage not forward of the front wallSch 2 Pt 1 Class 3 condition 1
Shed or garage floor areaSch 2 Pt 1 Class 3 condition 2 (as substituted by S.I. 338/2026)
Shed or garage heightSch 2 Pt 1 Class 3 condition 5
Shed use and finishesSch 2 Pt 1 Class 3 conditions 4 and 6
Detached house in the rear garden (Class 3A)Sch 2 Pt 1 Class 3A (inserted by S.I. 340/2026)
Bin or bicycle store (Class 62)Sch 2 Pt 1 Class 62 (inserted by S.I. 341/2026)
Heat pumps and external wall insulationSch 2 Pt 1 Class 2(d) (as substituted by S.I. 342/2026); Class 63 (inserted by S.I. 341/2026)
Front wall, fence or gate heightSch 2 Pt 1 Class 5 condition 1 (as made, unamended)
Other walls, fences and gatesSch 2 Pt 1 Class 5 condition 1 (as made, unamended)
Wall capping, render and no palisade fencesSch 2 Pt 1 Class 5 conditions 2 and 3 (as made, unamended)
Paths, landscaping and hard surfacesSch 2 Pt 1 Class 6(a) and 6(b) (as substituted by S.I. 454/2011)
Front porchSch 2 Pt 1 Class 7 conditions 1 to 3 (as made, unamended)
No article 9 restriction appliesPDR 2001 art 9(1) (as amended)

What it does not cover

Indicative only. This checks a few measurable conditions of exempted development for houses in Ireland. It does not cover every condition and is not a declaration under section 5 of the Planning and Development Act 2000. Exemptions do not apply where article 9 restrictions bite: for example, where works contravene a condition of a planning permission, create a traffic hazard, widen an access onto a road over 4 m wide, affect a protected structure or an architectural conservation area, or extend an unauthorised structure. Check with your planning authority, or ask it for a section 5 declaration, before building.

Check a design against it

Open your project in Plotlay, choose Design codes, pick Ireland exempted development for houses (PDR 2001 Sch 2 Part 1) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →

Other packs for Ireland

Every design code pack →