Design codes · Ireland
Ireland TGD M 2022: access in buildings other than dwellings (INDICATIVE)
Checks a new non-domestic building against TGD M 2022 Section 1: door effective clear widths (800 mm, and 1000 mm at the entrance of buildings used by the public), corridor widths, the width of a wheelchair accessible WC, a stair suitable for ambulant disabled people, and stair guarding height from TGD K. Ramps, passing places, door forces, WC layout and floor and balcony guarding are hand checks. Does not cover car parking, lifts, seating, signage, fire escape (TGD B) or existing buildings (Section 2).
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
Building Regulations 1997 (S.I. No. 497 of 1997) as amended, Second Schedule Parts M and K, and Technical Guidance Documents M and K
TGD M 2022 Access and Use, Section 1 (new buildings other than dwellings), for Part M as amended by S.I. No. 608 of 2022; the document applies to works from 1 January 2024. TGD K 2014 Diagram 6 for guarding heights. Both the current editions listed on gov.ie, read on gov.ie (assets.gov.ie) 2026-10-29. Source: Technical Guidance Document M, Access and Use (2022), gov.ie.
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Door effective clear width: 800 mm min | TGD M 2022 paras 1.2.4 and 1.3.3.2, Table 3, Diagram 10 |
| Entrance doors of buildings used by the public: 1000 mm min | TGD M 2022 para 1.2.4, Table 3 and note (b) |
| Corridor unobstructed width: 1200 mm min | TGD M 2022 para 1.3.3.3 |
| Wheelchair accessible WC width: 1800 mm (1500 mm in small buildings) | TGD M 2022 paras 1.4.3.1 and 1.4.5, Diagrams 15a and 15b |
| Stair for ambulant disabled people: rise 150 to 180 mm | TGD M 2022 para 1.3.4.3 |
| Stair for ambulant disabled people: going 300 mm min | TGD M 2022 para 1.3.4.3 |
| Stair for ambulant disabled people: clear width 1200 mm min | TGD M 2022 para 1.3.4.3 |
| Guarding on stair flights: 900 mm | TGD K 2014 paras 1.1.18 to 1.1.20, Diagram 6 |
| Stairs for ambulant disabled people: landings, flights, nosings | TGD M 2022 para 1.3.4.3 |
| Ramps: gradient, flight length, width and landings | TGD M 2022 paras 1.1.3.4 and 1.3.4.4, Table 2, Diagram 3 |
| Corridor passing places and level floors | TGD M 2022 para 1.3.3.3 |
| Door opening forces and space beside the leading edge | TGD M 2022 paras 1.2.4 and 1.3.3.2 |
| Wheelchair accessible unisex WC: where and how laid out | TGD M 2022 paras 1.4.3.1, 1.4.4 and 1.4.5, Diagrams 15 to 17 |
| Guarding to floors, landings and balconies: 1100 mm | TGD K 2014 paras 2.2 to 2.6, Diagram 6 |