Design codes · Ireland
Ireland Building Regulations TGDs for dwellings: stairs, escape windows, access (INDICATIVE)
Checks a new house against figures in the Irish Technical Guidance Documents: private stair rise, going, pitch, 2R+G, width, flight length and guarding height (TGD K), bedroom escape window size and sill (TGD B Volume 2), entrance and inside door widths and corridor widths (TGD M Section 3), and the 2.4 m ceiling height TGD F suggests. Headroom, landings, handrails, balcony and window guarding, the accessible approach and WC, and ventilation openings are hand checks. Does not cover structure, fire separation, energy (TGD L), drainage, apartments' escape (TGD B Volume 1) or planning.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
Building Regulations 1997 (S.I. No. 497 of 1997) as amended, Second Schedule Parts B, F, K and M, and the Technical Guidance Documents published by the Department of Housing, Local Government and Heritage
TGD K 2014 Stairways, Ladders, Ramps and Guards (works from 1 January 2015, S.I. No. 180 of 2014); TGD B 2017 Fire Safety Volume 2 Dwelling Houses (works from 1 July 2017); TGD F 2019 Ventilation (works from 1 November 2019); TGD M 2022 Access and Use (S.I. No. 608 of 2022; the document applies to works from 1 January 2024). Each is the current edition listed on gov.ie, read on gov.ie (assets.gov.ie) 2026-10-29. Source: Technical Guidance Documents K (2014), B Volume 2 (2017), F (2019) and M (2022), gov.ie.
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Private stair rise: 220 mm max | TGD K 2014 para 1.1.4, Table 1 |
| Private stair going: 220 mm min | TGD K 2014 para 1.1.4, Table 1 |
| Private stair pitch: 42 degrees max | TGD K 2014 para 1.1.4, Table 1 |
| Two risers plus a going: 550 to 700 mm | TGD K 2014 Table 1, note 4 |
| Private stair clear width: 800 mm min | TGD K 2014 para 1.1.10 |
| No more than 16 risers in a flight | TGD K 2014 para 1.1.11 |
| Stair guarding in a house: 900 mm | TGD K 2014 paras 1.1.18 to 1.1.20, Diagram 6 |
| Stair headroom: 2 m | TGD K 2014 para 1.1.9, Diagram 3 |
| Landings at the top and bottom of every flight | TGD K 2014 paras 1.1.13 and 1.1.14, Diagram 5 |
| Stair handrails: 900 to 1000 mm | TGD K 2014 para 1.1.17 |
| Open risers and guarding: 100 mm sphere | TGD K 2014 paras 1.1.7, 1.1.8 and 1.1.19 |
| Guarding to floors, balconies and roofs: 1100 mm | TGD K 2014 paras 2.2 and 2.3, Diagram 6 |
| Low windows high above the ground | TGD K 2014 paras 2.4 and 2.7, Diagrams 7 and 9 |
| An escape window in every bedroom | TGD B Vol 2 2017 paras 1.3.7.1 and 1.3.9.1 |
| Escape window clear opening: 0.33 m² min | TGD B Vol 2 2017 para 1.3.7.1(a) |
| Escape window clear width: 450 mm min | TGD B Vol 2 2017 para 1.3.7.1(a) |
| Escape window clear height: 450 mm min | TGD B Vol 2 2017 para 1.3.7.1(a) |
| Escape window: bottom of the opening 1100 mm max above the floor | TGD B Vol 2 2017 para 1.3.7.1(b) |
| Accessible entrance door effective clear width: 800 mm min | TGD M 2022 para 3.2.2 |
| Doors to habitable rooms on the entrance storey: 775 mm min | TGD M 2022 para 3.3.2.1, Table 5, Diagram 35 |
| Corridors on the entrance storey: 900 mm min | TGD M 2022 para 3.3.2.1, Table 5, Diagram 35 |
| Accessible approach and level entrance | TGD M 2022 paras 3.1.2.1 to 3.1.2.5 and 3.2.2 |
| Visitable WC at entry level | TGD M 2022 paras 3.4.2 and 3.4.3, Diagrams 36 and 37 |
| Habitable room ceiling height: 2.4 m suggested | TGD F 2019 para 1.2.1.7, Diagram 3 |
| Ventilation openings | TGD F 2019 paras 1.2.4.1 to 1.2.4.6, Table 3 |