Design codes · United States
Portland, Oregon single-dwelling zones (RF to R2.5): setbacks, height, coverage, outdoor area, accessory buildings, fences, ADUs
Covers the base single-dwelling zone standards of Portland Zoning Code Chapter 33.110 for one house: front, side and rear setbacks, height, building coverage on small lots, required outdoor area, detached accessory structure height, fences, and the size and location of an accessory dwelling unit (33.205). FAR, the coverage formula for larger lots, garage rules and the setback exceptions are hand checks. Does not cover plan districts, overlay zones, flag lots, narrow lots, middle housing (duplex to fourplex) bonus options, trees (Title 11) or building code.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
City of Portland Zoning Code (Title 33), Chapter 33.110 Single-Dwelling Zones, and Chapter 33.205 Accessory Dwelling Units
Chapter 33.110 as published on portland.gov (pages dated 10/1/24 to 3/1/25; last amendment Ord. 191961 effective 3/1/25; Update Packet #215 of 10/24/25 changed only typos on pages 9-10 and 29-30), and the same text in the full printable Title 33 effective July 1, 2026; Chapter 33.205 pages dated 10/1/24. Read 2026-10-14. Ordinance 192213 (Regulatory Improvement Code Amendment Package 11) takes effect November 1, 2026 and is not reflected here. Oregon's middle housing law (HB 2001, 2019) is already built into this chapter through the Residential Infill Project (effective August 1, 2021); no 2025 or 2026 change to the 33.110 figures used here was found. Source: City of Portland Zoning Code, Chapter 33.110 (portland.gov).
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| House front setback | 33.110.220.B, Table 110-4 |
| House side setback | 33.110.220.B, Table 110-4 |
| House rear setback | 33.110.220.B, Table 110-4 |
| Garage entrance setback: 18 ft | 33.110.220.B, Table 110-4 |
| Maximum building height | 33.110.215.B, Table 110-4; 33.930.050 |
| Building coverage on lots under 3,000 sq ft: 50% | 33.110.225.B, Table 110-5 |
| Building coverage on lots of 3,000 sq ft or more | 33.110.225.B, Table 110-5 |
| Floor area ratio | 33.110.210, Table 110-4 |
| Required outdoor area: size | 33.110.240, Table 110-4 |
| Required outdoor area: minimum dimension | 33.110.240.B, Table 110-4 |
| Detached covered accessory structures: 20 ft high | 33.110.245.C.1 |
| Accessory structures in side and rear setbacks | 33.110.245.C.2 |
| Accessory structure coverage | 33.110.245.C.3 |
| Fences in the front setback: 3 1/2 ft | 33.110.275.C.1 |
| Fences in side and rear setbacks: 8 ft | 33.110.275.C.2 |
| Accessory dwelling unit: 800 sq ft | 33.205.040.C.1 |
| Accessory dwelling unit location | 33.205.040.C.2 and C.3 |