Design codes · United States
Austin, Texas SF-3 family residence district: setbacks, height, coverage, setback planes, fences
Covers the SF-3 site development regulations in Austin's Land Development Code for a house or a two or three unit project: front, interior side and rear setbacks, height, building coverage, the Subchapter F side and rear setback plane, small accessory building setbacks and solid fence height. Impervious cover, FAR, the street side setback and garage placement are hand checks. Does not cover neighborhood plan or historic overlays, watershed rules, compatibility standards, trees or building code.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
City of Austin Land Development Code, Title 25, Chapter 25-2 Zoning (Section 25-2-492 site development regulations, 25-2-555, 25-2-773, 25-2-899, and Subchapter F Residential Design and Compatibility Standards)
Austin Land Development Code on Municode, Supplement 174, codified through Ordinance No. 20260423-048 (effective September 1, 2026), read 2026-10-14. The 25-2-492 table was last amended by Ordinance No. 20251023-063 (effective November 3, 2025); the HOME amendments (Ordinance No. 20231207-001, effective December 18, 2023, allowing up to three units on an SF-3 lot) are included. No later change to the SF-3 figures used here was found. Source: Austin Land Development Code, Chapter 25-2 (Municode, the City's official online code publisher).
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Front yard setback | LDC 25-2-492(D) table; 25-2-773(B)(2) |
| Interior side yard setback: 5 ft | LDC 25-2-492(D) table |
| Rear yard setback: 10 ft | LDC 25-2-492(D) table; 25-2-773(B)(3) |
| Maximum height | LDC 25-2-492(D) table; Subchapter F 2.2 and 3.4 |
| Building coverage: 40% | LDC 25-2-492(D) table; 25-2-773(B)(6) |
| Impervious cover: 45% | LDC 25-2-492(D) table; 25-2-773(B)(7); 25-1-23 |
| Side and rear setback planes (Subchapter F) | Subchapter F 2.6.A and B |
| Floor area limit (Subchapter F) | Subchapter F 2.1; LDC 25-2-773(E) |
| Small accessory building: 5 ft from side and rear lines | LDC 25-2-555(B); 25-2-492(D) table |
| Garage placement for 2 and 3 unit uses | LDC 25-2-773(C)(3) |
| Solid fence on a property line: 6 ft | LDC 25-2-899(D) to (H) |