Design codes · United States
2010 ADA Standards for Accessible Design: doors, routes, toilet rooms, stairs (INDICATIVE)
Fuller than the Accessibility basics pack: door clear width, route width, toilet room turning space, accessible water closet space depth, and stair risers and treads are measured; door clearances and hardware, thresholds, ramps, handrails, grab bars, lavatories, reach, protruding objects, kitchens and parking are hand checks. It tests every proposed door, hall and toilet room, though the Standards apply only where the Chapter 2 scoping calls for them, and leaves out scoping counts, elevators, signs, assembly seating and dwelling units (809). The Standards print inches with rounded millimetres in brackets and name no governing unit (104); Plotlay tests the inch figure.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
2010 ADA Standards for Accessible Design, US Department of Justice (28 CFR 35.151 and 36 CFR part 1191 appendices B and D for Title II; 28 CFR part 36 subpart D and the same appendices for Title III)
2010 ADA Standards as published by the US Department of Justice on ada.gov, read 2026-10-29. Adopted in the revised ADA regulations of 15 September 2010; new construction and alterations started on or after 15 March 2012 must comply. Source: US Department of Justice, 2010 ADA Standards for Accessible Design (ada.gov).
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Door clear width at least 32 in (815 mm) | 2010 ADA Standards 404.2.3 |
| Deep doorways and projections into the opening | 2010 ADA Standards 404.2.3 |
| Maneuvering clearances at doors | 2010 ADA Standards 404.2.4, Tables 404.2.4.1 and 404.2.4.2 |
| Door hardware 34 to 48 in high, thresholds 1/2 in | 2010 ADA Standards 404.2.5, 404.2.7, 404.2.8, 404.2.9, 303 |
| Accessible route clear width at least 36 in (915 mm) | 2010 ADA Standards 403.5.1 |
| Passing spaces, 180 degree turns and route slopes | 2010 ADA Standards 403.3, 403.5.2, 403.5.3, 402.2 |
| Turning space in toilet and bathing rooms: 60 in (1525 mm) circle | 2010 ADA Standards 603.2.1, 304.3.1 |
| Wheelchair accessible water closet space at least 56 in (1420 mm) deep | 2010 ADA Standards 604.3.1, 604.8.1.1 |
| Toilet compartment doors and toe clearance | 2010 ADA Standards 604.8.1.2, 604.8.1.4 |
| Water closet position, seat height and grab bars | 2010 ADA Standards 604.2, 604.4, 604.5, 609.4 |
| Lavatories and sinks: 34 in high, knee clearance | 2010 ADA Standards 606.2, 606.3, 606.5, 306, 305.3 |
| Clear floor space 30 by 48 in and reach ranges 15 to 48 in | 2010 ADA Standards 305.3, 305.7, 308.2, 308.3 |
| Protruding objects and 80 in headroom | 2010 ADA Standards 307.2, 307.4 |
| Ramps: 1:12 slope, 30 in rise, 36 in wide, 60 in landings | 2010 ADA Standards 405.2 to 405.8 |
| Stair risers no more than 7 in (180 mm) | 2010 ADA Standards 504.2 |
| Stair risers at least 4 in (100 mm) | 2010 ADA Standards 504.2 |
| Stair treads at least 11 in (280 mm) deep | 2010 ADA Standards 504.2 |
| Stairs: no open risers, nosing profile | 2010 ADA Standards 504.3, 504.5 |
| Handrails: both sides, 34 to 38 in, 12 in extensions | 2010 ADA Standards 505.2, 505.4, 505.10 |
| Kitchen clearance: 40 in, or 60 in in a U-shaped kitchen | 2010 ADA Standards 804.2 |
| Accessible parking spaces and access aisles | 2010 ADA Standards 502.2, 502.3, 208.2 |