NZ Building Code D1 accessible routes (INDICATIVE)

Covers the accessible route figures of D1/AS1: door clear opening, route width and the turning circle in accessible accommodation units (measured), plus hand checks for ramps, door handles and which buildings must be accessible. Use it for public, commercial and communal residential buildings, or as a reference for an accessible home. Does not cover accessible toilets (G1/AS1), parking, lifts, stairs or signs.

6rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
1 January 2017instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

New Zealand Building Code clause D1 Access routes, Acceptable Solution D1/AS1 (citing NZS 4121:2001)

D1/AS1 second edition, amendment 6, effective 1 January 2017; listed as current on MBIE Building CodeHub, seen 2026-10-14. Source: MBIE Acceptable Solution D1/AS1 Access Routes (building.govt.nz).

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Accessible door clear opening at least 760 mmD1/AS1 7.0.3
Accessible route clear width at least 1200 mmD1/AS1 2.2.1
Accessible accommodation units: 1500 mm turning circleD1/AS1 9.2.1
Accessible ramp no steeper than 1:12, 1200 mm wideD1/AS1 3.1.1, Table 3; 3.1.3; 3.2
Accessible door handles 900 mm to 1200 mm above the floorD1/AS1 7.0.5
Which buildings must be accessibleBuilding Act 2004 s 118; Building Code D1.3.2; D1/AS1 1.1.1, 10.1.1

What it does not cover

INDICATIVE only. Acceptable Solutions are one way to comply with the New Zealand Building Code; other ways may comply. Accessible route requirements apply to buildings covered by section 118 of the Building Act 2004, not to private houses. NZS 4121:2001 figures are used only where D1/AS1 restates them. Door clear widths, hall widths and turning circles are measured; the rest are reminders. Your building consent authority decides compliance.