Plotlay Open the app →

Design codes · New Zealand

NZ exempt building work (Building Act 2004 Schedules 1 and 1A)

Covers the Building Act 2004 Schedule 1 exemptions most homeowners use (sheds and sleepouts, carports, verandas, fences, decks, retaining walls and other small work) and the Schedule 1A route for a small stand-alone dwelling (granny flat) of up to 70 m² without a building consent. Does not cover the Building Code itself, district plan rules (yards, height, coverage) or the planning standard for granny flats beyond a reminder, and it does not decide whether work is exempt: the council can confirm that in writing.

24rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
26 September 2026instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

Building Act 2004, Schedule 1 (building work for which building consent not required) and Schedule 1A (small stand-alone dwellings)

Building Act 2004 as at 26 September 2026 (legislation.govt.nz, seen 2026-10-14). Includes the Building (Exempt Roof-mounted Solar Panel Arrays and Building Work) Order 2025 (from 23 October 2025) and Schedule 1A inserted by the Building and Construction (Small Stand-alone Dwellings) Amendment Act 2025 (from 15 January 2026). Planning rules for granny flats are in the Resource Management (National Environmental Standards for Detached Minor Residential Units) Regulations 2025, as at 11 September 2026. Source: Building Act 2004 (legislation.govt.nz).

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Detached shed or sleepout floor areaBA04 Sch 1 cl 3(1)(b), 3A(1)(b), 3B(1)(b)(ii), 43(1)(c)(ii)
Shed or sleepout must be detachedBA04 Sch 1 cl 3(1), 3A(1), 3B(1), 43(1)
Shed or sleepout height (single storey)BA04 Sch 1 cl 3(1)(a), 3A(1)(a), 3B(1)(b)(i), 43(1)(c)(i)
Shed or sleepout over 10 m²: 1 m from boundariesBA04 Sch 1 cl 3A(2), 3B(2), 43(2)
Shed or sleepout use: no plumbing, sleeping limitsBA04 Sch 1 cl 3(1)(c)-(d), 3A(1)(d)-(f), 3B(1)(b)(iii)-(v)
Carport floor areaBA04 Sch 1 cl 18, 18A
Porch or veranda floor areaBA04 Sch 1 cl 17, 17A
Porch or veranda must be on an existing buildingBA04 Sch 1 cl 17(a), 17A(b)(i)
Fence or wall heightBA04 Sch 1 cl 21
PergolasBA04 Sch 1 cl 6
Decks and platforms: fall heightBA04 Sch 1 cl 24
Retaining wallsBA04 Sch 1 cl 20; cl 41
Shade sailsBA04 Sch 1 cl 19
Water tanks and poolsBA04 Sch 1 cl 23
Outdoor fireplaces and ovensBA04 Sch 1 cl 28A
Small stand-alone dwelling: floor areaBA04 Sch 1A cl 1(c)
Small stand-alone dwelling: single storey, height and floor levelBA04 Sch 1A cl 1(d), 2(1)(b) to (d)
Small stand-alone dwelling: 2 m from side boundariesBA04 Sch 1A cl 2(1)(f)
Small stand-alone dwelling: 2 m from the rear boundaryBA04 Sch 1A cl 2(1)(f)
Small stand-alone dwelling: 2 m from the street boundaryBA04 Sch 1A cl 2(1)(f)
Small stand-alone dwelling: 2 m from other residential buildingsBA04 Sch 1A cl 2(1)(f)
Small stand-alone dwelling: construction, services and council stepsBA04 Sch 1A cl 2; s 42B
Granny flat planning standard (no resource consent)Resource Management (National Environmental Standards for Detached Minor Residential Units) Regulations 2025, regs 5 and 6
Exempt work must still meet the Building Code and the district planBA04 s 17; s 42A; Sch 1

What it does not cover

Indicative only. This covers the Schedule 1 and 1A exemptions most homeowners use, not every condition. Exempt work must still meet the Building Code and your district plan, and the council can confirm in writing whether work is exempt. If in doubt, ask your council or a licensed building practitioner.

Check a design against it

Open your project in Plotlay, choose Design codes, pick NZ exempt building work (Building Act 2004 Schedules 1 and 1A) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →

Other packs for New Zealand

Every design code pack →