Auckland Unitary Plan: Single House and Mixed Housing Suburban zones

Covers the main built form standards of Auckland's Residential - Single House zone (H3) and Residential - Mixed Housing Suburban zone (H4): building height, height in relation to boundary, yards, impervious area, building coverage, landscaped area, outdoor living space (H4), fences and walls. Does not cover the H4 alternative height in relation to boundary, outlook and daylight standards (reminders only), overlays, precincts, special character, natural hazards, or Plan Change 120.

16rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
1 July 2026instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

Auckland Unitary Plan (Operative in part), Chapter H3 Residential - Single House Zone and Chapter H4 Residential - Mixed Housing Suburban Zone

Chapter PDFs dated July 2026 (Auckland Council, seen 2026-10-14). Plan Change 78 (MDRS intensification) was withdrawn on 9 October 2025, so the MDRS no longer apply as permitted standards in these zones. Proposed Plan Change 120 (Housing Intensification and Resilience) was notified in late 2025, with amendments approved for renotification in July 2026; it is not operative and decisions are expected in 2027. Some PC120 activity rules have immediate legal effect under RMA s 86B(3)(f) (marked in the chapters); the standards below are the operative ones. Source: Auckland Unitary Plan (Operative in part), chapters H3 and H4.

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Building heightAUP H3.6.6 / H4.6.4
Height in relation to boundaryAUP H3.6.7 / H4.6.5
Front yardAUP H3.6.8 / H4.6.7 Table
Side yardAUP H3.6.8 / H4.6.7 Table
Rear yardAUP H3.6.8 / H4.6.7 Table
Sheds and carports: side and rear yardsAUP H3.6.8 / H4.6.7 Table
Maximum impervious areaAUP H3.6.9 / H4.6.8
Maximum building coverageAUP H3.6.10 / H4.6.9
Minimum landscaped areaAUP H3.6.11(1) / H4.6.10(1)
Front yard landscapingAUP H3.6.11(2) / H4.6.10(2)
Outdoor living space (Mixed Housing Suburban)AUP H4.6.13(1)
Front fences and wallsAUP H3.6.12(1)(a) / H4.6.14(1)(a)
Side and rear fences and wallsAUP H3.6.12(1)(b) / H4.6.14(1)(b)
Number of dwellingsAUP Table H3.4.1 (A3), (A5); Table H4.4.1
Outlook and daylight (Mixed Housing Suburban)AUP H4.6.11, H4.6.12
Plan Change 120 and other rulesAUP Proposed Plan Change 120; Auckland-wide chapters

What it does not cover

Reference only. These are the core H3 and H4 standards as printed in July 2026, simplified; overlays, precincts, special character areas, natural hazard rules, Plan Change 120 provisions with legal effect and Auckland-wide rules (chapter E) can change them. Check the Auckland Unitary Plan for your site, or ask Auckland Council or a planner.

Check a design against it

Open your project in Plotlay, choose Design codes, pick Auckland Unitary Plan: Single House and Mixed Housing Suburban zones and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.