Design codes · New South Wales
NSW secondary dwellings (granny flats): complying development
Covers the main measurable complying development standards for a detached secondary dwelling (granny flat) in Zone R1 to R4 under the Housing SEPP: lot area and width, site coverage, the 60 m² floor area, front, side and rear setbacks of the granny flat, outbuilding and fence heights, landscaped area and principal private open space. The total floor area, height of the granny flat, height-based extra setbacks, privacy, decks, earthworks and the Codes SEPP land exclusions are hand checks. There is no exempt development pathway for a secondary dwelling; development applications are noted only.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
State Environmental Planning Policy (Housing) 2021, Chapter 3, Part 1 (sections 49 to 56) and Schedule 1 Complying development: secondary dwellings
Text checked against the official point-in-time HTML for the version from 12 December 2025 (legislation.nsw.gov.au, archived copy). Schedule 1 was last amended in 2022 (2022 (349), 2022 (451)); the later versions to 3 July 2026 in the legislative history are precinct, local plan and concurrence amendments that do not name secondary dwellings. Source: NSW legislation: State Environmental Planning Policy (Housing) 2021, Schedule 1.
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Zone and complying development pathway | s 50; s 54(1), (2)(a), (b) |
| Lot area at least 450 m² | s 54(2)(c) |
| Lot width at the building line | Sch 1, s 2(1)(b) |
| Maximum site coverage of all development | Sch 1, s 3 |
| Secondary dwelling floor area no more than 60 m² | Sch 1, s 4(1); s 54(3)(f) |
| Total floor area of the principal and secondary dwellings | Sch 1, s 4(2), (3) |
| Height of the secondary dwelling (8.5 m) | Sch 1, s 6(1) |
| Outbuildings no higher than 4.8 m | Sch 1, s 6(2)(a) |
| Fences no higher than 1.8 m | Sch 1, s 6(2)(b) |
| Front setback: average of the 2 nearest houses | Sch 1, s 7(1)(a), s 12(1), (2) |
| Front setback where there are no 2 houses within 40 m | Sch 1, s 7(1)(b) |
| Secondary, parallel and classified road, and public reserve setbacks | Sch 1, s 7(2), (3), s 8, s 11(1) |
| Side setback of the secondary dwelling | Sch 1, s 9(1) |
| Extra side setback for parts over 3.8 m high | Sch 1, s 9(2), (3); s 12(4), (5) |
| Rear setback of the secondary dwelling | Sch 1, s 10(1) |
| Balconies, decks and terraces | Sch 1, s 5 |
| Front door, windows and articulation zone | Sch 1, s 13, s 14 |
| Privacy screens | Sch 1, s 15 |
| Minimum landscaped area | Sch 1, s 16(1), (3) |
| Half the landscaped area behind the building line | Sch 1, s 16(2) |
| Principal private open space more than 24 m² | Sch 1, s 17 |
| Principal private open space more than 4 m wide | Sch 1, s 17(3)(b) |
| Earthworks, drainage and protected trees | Sch 1, s 18 to 20 |
| Secondary dwelling within the principal dwelling | s 54(3) |
| Development application route | s 52; s 53 |