Plotlay Open the app →

Design codes · New South Wales

NSW Housing Code (complying development)

Covers the main measurable Housing Code standards for a new or altered 1 or 2 storey dwelling house and its outbuildings on a lot in Zone R1, R2, R3, R4 or RU5: lot size and width, height, gross floor area, setbacks (including the side setback plane for upper parts), landscaped area, principal private open space, upper floor window privacy, car parking, garage doors, detached structures and fences. Does not cover the land exclusions in Part 1 (heritage, bush fire, flood, environmentally sensitive land), neighbours’ setbacks, deck floor levels, earthworks or the Schedule 6 conditions, which are hand checks. Dual occupancies, manor houses and terraces are in the separate Low Rise Housing Diversity Code pack.

39rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
11 September 2026instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

State Environmental Planning Policy (Exempt and Complying Development Codes) 2008, Part 3 Housing Code

Current version on legislation.nsw.gov.au (shown as current from 11 September 2026). Clause text checked against the official whole-instrument HTML as archived on 18 July 2026, which includes amendments to 2026 (345); Part 3 was last amended in 2024 (2024 (609), 2024 (659)). Source: NSW legislation: Exempt and Complying Development Codes SEPP 2008, Part 3.

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Lot area at least 200 m²cl 3.1(3)(b)
Lot width at least 6 m at the building linecl 3.1(3)(c), (g)
Zone, one dwelling house and road accesscl 3.1(3)(a), (d), (e); cl 3.2
House height no more than 8.5 mcl 3.8
One or two storeyscl 3.1(1), (2)
Gross floor area of all buildingscl 3.9(1) table (and cl 3.19)
Front setback: average of the 2 nearest housescl 3.10(1), (2)
Front setback where there are no 2 houses within 40 mcl 3.10(3)
Secondary, parallel and classified road setbackscl 3.10(11) to (15)
Side setback (lowest parts of the house)cl 3.10(4) table
Side setback plane for parts over 5.5 m high (lot 6 to 10 m wide)cl 3.10(4) table
Side setback plane for parts over 4.5 m high (lot over 10 to 18 m wide)cl 3.10(4) table
Side setback plane for parts over 4.5 m high (lot over 18 to 24 m wide)cl 3.10(4) table
Walls within 900 mm of a side boundarycl 3.10(7) to (9); cl 3.32
Rear setback (parts up to 4.5 m high)cl 3.10(10) table
Rear setback of parts over 4.5 m highcl 3.10(10) table
Minimum landscaped areacl 3.13(1) (and cl 3.27(1))
Where the landscaped area must gocl 3.13(2), (3)
Principal private open space areacl 3.13(4)
Principal private open space at least 3 m by 3 mcl 3.13(4A)
Door and window facing the streetcl 3.14
Upper floor habitable room windows within 3 m of a side or rear boundary need a privacy screencl 3.15(1)(a), (2)
Privacy screens for windows 3 to 6 m from a boundarycl 3.15(1)(b), (2)
Privacy screens and limits for raised side and rear deckscl 3.12, 3.12A, 3.15(3)
At least 1 off-street car spacecl 3.16(1)
Garage or carport setback from the primary road (5.5 m floor)cl 3.16(5); cl 3.23(5)
Garage or carport behind the building linecl 3.16(5); cl 3.23(5); cl 3.2(1)(g)
Garage door width facing a roadcl 3.16(6); cl 3.23(9)
Garages on lots under 8 m wide and battle-axe lotscl 3.16(3), (4); cl 3.23(2), (3)
Detached outbuildings, carports and decks no higher than 4.5 mcl 3.18
Floor area of detached decks, sheds and carportscl 3.20
Detached outbuildings behind the building linecl 3.21(1)
Detached structure setback from side boundariescl 3.21(2), (8); cl 3.23(7); cl 3.24(2)
Detached deck floor no higher than 600 mmcl 3.24(1)
Swimming poolscl 3.28
Front fence no higher than 1.2 mcl 3.29(3)(a), (4)
Side and rear fences no higher than 1.8 mcl 3.29(2)(a), (e)
Excavation, fill and retaining wallscl 3.30
Bush fire, flood and protected treescl 3.4, 3.5, 3.33

What it does not cover

Indicative only. This checks some of the Housing Code standards for a new or altered 1 or 2 storey dwelling house and its outbuildings, not every clause, and cannot confirm that a lot qualifies for complying development: land exclusions (heritage, bush fire attack level, flood, environmentally sensitive land and others in Part 1 of the SEPP) are not tested. Only an accredited certifier or council can issue a complying development certificate. Lot width is taken from the street frontage, but the code measures it at the building line. The Housing Code has no site coverage control: it limits the gross floor area of all buildings on the lot instead (cl 3.9), which is a figure you enter. Dual occupancies, manor houses and terraces fall under the Low Rise Housing Diversity Code (Part 3B), and Zone R5 and rural lots under the Rural Housing Code (Part 3A); neither is covered here. If a proposal does not meet these standards it may still be approved through a development application to council.

Check a design against it

Open your project in Plotlay, choose Design codes, pick NSW Housing Code (complying development) and run the check. It is free in your browser. Step by step: choose the codes for a site and run a code check.

Open Plotlay →

Other packs for New South Wales

Every design code pack →