Guide 8 · design codes
Rule pack format
A guide for councils, estate developers, body corporates, design studios, consultants and anyone who wants a set of planning or design rules checked against a Plotlay project. Version 1.3, 2 November 2026 (1.3 adds Excel workbooks and tables with flexible headers, templates to download, export of any pack, a rule's target for a figure with a plus or minus, a rule's source, the pack's author, and fit-out measures such as a vanity's top height; 1.2 added country, applies_to, units, a rule's confidence, stair pitch and clear opening area).
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
What a pack is
A rule pack is a list of checks Plotlay runs against a drawn project: a setback, a height, a site coverage, a fence height, a door width. Each check reports one of:
| Result | Meaning |
|---|---|
| PASS | Meets the rule. |
| WARN | Passes but is close to the limit (inside its warn band), or is just outside it but within the rule's tolerance. |
| FAIL | Does not meet the rule. |
| UNKNOWN | Not measured yet, or depends on a fact nobody has entered. UNKNOWN is never a pass. |
Plotlay ships packs for the Australian states, New Zealand, England, Scotland, Wales, Ireland, the US, Canada, Singapore and some European countries, listed with their sources in design-code-packs.md. Anyone can write their own in an Excel workbook, a CSV or TSV table, JSON or YAML and import it into a project (Design codes, Import a pack), or have an AI agent connected to Plotlay build one from a document.
The quickest start is a template: Design codes, Import a pack, Download a template (Excel, CSV, JSON or YAML), or the connector's get_rule_pack_template. Any pack, a built-in code included, can also be exported in each format (Design codes, Export…; the connector's export_rule_pack), changed, and imported again. See Tables: Excel, CSV and TSV, below.
A project keeps a copy of each pack it uses, at its version. A later check gives the same answer until someone chooses a newer version.
A small example
{
"id": "seaview-estate",
"name": "Seaview Estate design guidelines",
"kind": "template",
"jurisdiction": "Seaview Estate",
"version": "2026.1",
"published": "2026-03-01",
"source": "Seaview Estate Design Guidelines, March 2026",
"source_url": "https://example.org/seaview-guidelines.pdf",
"disclaimer": "The developer's design approval is still needed.",
"rules": [
{ "id": "front-setback", "title": "House front setback", "ref": "4.1",
"each": "dwellings", "metric": "front_setback_mm", "op": ">=", "limit": 6000, "unit": "mm",
"tolerance": 200, "note": "Porches may sit 1.5 m forward of the building line." },
{ "id": "fence", "title": "Front fence height", "ref": "6.2",
"each": "fences", "where": { "front": true }, "metric": "height_mm", "op": "<=", "limit": 1200, "unit": "mm" },
{ "id": "colours", "title": "Roof and wall colours", "ref": "5.3",
"each": "site", "op": "check", "note": "From the approved palette only." }
]
}
Pack fields
| Field | Required | What it is |
|---|---|---|
id |
yes for sharing | Short id: lower case letters, digits and dashes. The same id at a new version is an update. |
name |
yes | What the pack is. |
kind |
no | code (a design code or council document), template (your own checks, not an official code), practice (common practice). Reports say when a pack is a template. |
jurisdiction |
yes for sharing | NSW, VIC, NZ, GB-ENG, IE, US, CA, FR, EU, or your own name for it. The picker groups packs by region from it: Australia, New Zealand, International, Europe, UK and Ireland, Americas, Asia (REGIONS in src/core/rules.js). |
country |
no | The country (ISO 3166 code: GB, US), or EU or INTL for European and international standards. Left out, it comes from the jurisdiction. |
applies_to |
no | Who the pack is for, in plain words: "New houses and flats", "Buildings other than dwellings". |
units |
no | imperial or metric. An imperial pack's figures are shown in feet and inches as well, and are tested against the inch figure (below). Left out, a US pack is imperial and every other pack metric. A project drawn in feet and inches sees feet and inches on every pack. |
version |
yes for sharing | Any text: 2026.1, 3. Projects pin to it. |
published |
no | The date of the source document. |
instrument, instrument_version |
no | The document and the version or amendment the rules come from. |
effective |
no | The date that version took effect (2026-10-09). |
checked |
no | The date the rules were last checked against the source. |
description |
no | Two or three sentences: what the pack covers and what it does not. |
source, source_url |
yes for sharing | The document and a link to it. |
disclaimer |
no | Shown with the pack and on reports. Plotlay adds the reference-only line. |
author |
no | Who wrote or keeps the pack: a studio, a council team, a person. |
based_on |
no | Set by Plotlay on a copy: { "id", "version", "name" } of the pack it was copied from. |
short |
no | A short name put before each clause reference on reports (R-Codes 5.1.2). |
params |
no | Facts a person enters per project, below. |
indicative |
no | true for guidance only (building code notes, accessibility basics). |
rules |
yes | The checks. |
Rule fields
| Field | What it is |
|---|---|
id |
Short id, unique in the pack. |
title |
Plain words: "House front setback". |
ref |
The clause, standard or table: cl 3.10(3), Table B, B2-1. |
source |
The document the rule comes from, when it is not the pack's own (a studio's standards that draw on several documents). Reports show it. |
source_url |
A link to the clause, if the source has one. Otherwise the pack's link is used. |
each |
What the rule applies to: site, dwellings, buildings, structures, fences, rooms, openings, stairs, fitout, driveways, crossovers, trees, roofs, earthworks. |
where |
Which of those: { "role": "outbuilding" }, { "room_type": "bedroom" }, { "kind": "door" }, { "item": "vanity" }, { "front": true }, { "status": "proposed" }, { "layer": "Stage 2" }. A list means any of. |
metric |
What is measured (the table below). |
op |
<= < >= > == != between (limit [min, max]) in (limit [a, b]) exists check. |
limit |
The figure, in unit. Leave it out (or null) in a template still to be filled in: the rule reports UNKNOWN. |
target |
With op: "between": the figure aimed at, inside the limit. "limit": [830, 870], "target": 850 is 850 ± 20 mm, and reports show it that way. An uneven range is allowed: [1200, 1250] with target 1200 shows as 1,200 mm (−0, +50 mm). |
limit_from |
A limit that depends on a project fact or a site figure (below). |
applies_if |
The rule applies only in some cases (below). |
unit |
mm, m², %, °, or none. Lengths are millimetres. |
warn_within |
A pass this close to the limit is WARN. |
warn_within_pct |
The same, as a percentage of the limit. |
tolerance |
A value this far outside the limit is WARN, not FAIL: 6000 with tolerance 200 accepts 5800. (A target's plus or minus is not a tolerance: 850 ± 20 passes from 830 to 870 and fails outside. Use target.) |
min_width_mm |
On an area (pos_m2, pos_largest_m2, soft_pct, landscaped_pct, deep_soil_pct, permeable_pct): count only the parts at least this wide. For "25 m² with a minimum dimension of 3 m": pos_m2 >= 25, min_width_mm: 3000. |
sun |
For pos_sun_pct and neighbour_shadow_m2: { "date": "winter", "from": 9, "to": 15, "hours": 3 } (winter: 21 June south of the equator, 21 December north; or equinox). Solar time. |
envelope |
For envelope_excess_mm: { "base_mm": 3000, "angle_deg": 45 }, a plane rising at that angle from a line that high above each side and rear boundary. Where the angle depends on the way a boundary faces, give angles: [[0, 55], [90, 39], [180, 26]] (the bearing of the boundary's outward side from true north, and the angle; a boundary between two steps takes the lower). |
verified |
The date the figure was checked against its source, or false. |
confidence |
high: the figure was read in the official text; medium: in the authority's own guide to it. A figure less sure than that is left out of the pack. |
note |
What the rule says in plain words, its exceptions, and anything the check simplifies. |
op: "check" is for what a drawing can't measure (overlooking, overshadowing, materials, waterproofing). It is listed once, as UNKNOWN, for someone to check by hand. Put the figures in the note.
What can be measured
each |
Metrics |
|---|---|
site |
site_area_m2, lot_width_mm (the street frontage), coverage_pct (roofed area as % of the site: the house to the outside of its walls, eaves not included, plus roofed carports, verandahs and sheds), roofed_m2, soft_m2, soft_pct, landscaped_pct (turf and planted beds, parts at least 0.7 m wide unless the rule sets min_width_mm), deep_soil_pct (turf and planted beds), permeable_pct (turf, beds, gravel and areas marked permeable), pos_m2, pos_largest_m2, pos_min_dim_mm (the narrowest part of the largest private open space), pos_sun_pct (private open space with the rule's hours of sun), neighbour_shadow_m2 (shadow cast beyond the side and rear boundaries), garage_opening_mm and garage_frontage_pct (garage doors and carport openings facing the street), car_spaces (a project fact) |
dwellings |
front_setback_mm, min_side_setback_mm, rear_setback_mm (to the outside face of the walls), floor_area_m2 (footprint), envelope_excess_mm (height above the rule's envelope at the nearest wall), status (proposed when any part is), and the project facts building_height_mm, wall_height_mm, storeys, gfa_m2 |
buildings |
each separate building (the house, a granny flat, a studio): floor_area_m2, internal_area_m2, rooms, bedrooms, main (the largest), front_setback_mm, min_side_setback_mm, rear_setback_mm, forward_of_building_line, distance_to_main_mm. where: { "main": false } picks a second dwelling. |
structures |
carports, verandahs, sheds and pergolas (role: carport, verandah, outbuilding): floor_area_m2, post_height_mm, roof_height_mm, roof_pitch_deg, front_setback_mm, min_side_setback_mm, width_mm, length_mm, boundary_length_mm, forward_of_building_line, attached |
fences |
height_mm, length_mm, front, pool (a pool barrier) |
rooms |
floor_area_m2, min_dim_mm (the narrowest part), ceiling_height_mm (when measured or set), room_type (bedroom, bathroom, wc, laundry, kitchen, living, study, hall, garage, storage, other), wet, upper, floor_level_mm, turning_circle_mm (the largest circle clear of what is drawn in the room), work_triangle_mm, work_triangle_leg_min_mm, work_triangle_leg_max_mm (sink, cooktop and fridge in a kitchen) |
openings |
doors and windows: kind (door or window), width_mm (as drawn), clear_width_mm (set in the Inspector), height_mm, clear_area_m2 (clear width times height, once both are set: an escape window's opening), sill_mm, room, room_type, external, egress, upper, floor_level_mm, faces (street, side or rear), boundary_dist_mm (straight out from the wall to the boundary it faces) |
stairs |
stairs and outside steps, once their risers and height are set: rise_mm, going_mm, slope_mm (2 risers plus a going), pitch_deg (the angle of the flight from the rise and going), width_mm, risers, total_rise_mm, balustrade, balustrade_height_mm, external |
fitout |
fit-out and fittings drawn in a room (placed from Fit-out or the Library): top_mm (its top above the floor: the height it sits at plus its own height, as set in the Inspector), height_mm, base_mm (its underside above the floor: a wall-hung vanity, a mirror), width_mm (the longer side in plan), depth_mm (the shorter side), item (a plain name: vanity, shower for a shower recess or enclosure, bath, toilet, bench, wardrobe, mirror; anything else, its fit-out kind), kind (the fit-out kind or Library entry), room, room_type |
driveways |
width_mm, width_at_boundary_mm, gradient_pct, centreline_angle_deg |
trees, roofs, earthworks |
see list_rule_packs on the connector |
Shadows come from the site's own house, structures and fences on level ground: the neighbours' buildings are not modelled. Sun hours need the site's location and the building height.
Only a height someone measured or entered counts: drawing defaults never pass a rule.
Imperial codes
Lengths are millimetres and areas square metres in every pack, so one engine checks them all. A US code states its figures in inches and feet and prints a rounded metric figure beside them (32 in prints as 815 mm, though 32 in is 812.8 mm). Write the metric figure the code prints in limit, and the inch figure in the note. An imperial pack is tested against the inch figure the printed one stands for (the nearest quarter inch, or tenth of a square foot), so a door exactly 32 in clear passes a 32 in (815 mm) rule. Reports show both: ≥ 815 mm (32 in).
Facts the drawing doesn't hold: params and limit_from
Declare what a person must enter for the project:
"params": [
{ "id": "wa_r_code", "label": "R-Code density", "type": "select", "options": ["R20", "R30", "R40"] },
{ "id": "zoning_front_setback_mm", "label": "Front setback in your zoning code", "type": "number", "unit": "mm", "help": "From your local zoning code" }
]
Then a rule's limit can come from it:
- A table by a choice:
"limit_from": { "param": "wa_r_code", "values": { "R20": 6000, "R30": 4000 } } - Bands by a number or a site figure:
"limit_from": { "metric": "site.site_area_m2", "bands": [[300, 3000], [900, 4500], [null, 6500]] }(up to and including 300 m²: 3000; up to 900: 4500; more: 6500). A band's limit can be a share of the figure it keys on plus a constant:[450, { "scale": 0.25, "add": 150 }](25% of the site area plus 150) - The figure itself, for a template where the number comes from a local code:
"limit_from": { "param": "zoning_front_setback_mm" }
applies_if limits a rule to some cases: { "param": "nsw_zone", "in": ["R1", "R2"] }, { "metric": "site.site_area_m2", "between": [450, 100000] }, { "param": "storeys", "op": ">=", "value": 2 }. A list means all of them: [{ "param": "qld_code_version", "in": ["QHC 2026"] }, { "metric": "site.site_area_m2", "op": "<", "value": 2000 }].
Until a fact is entered, its rules report UNKNOWN and say which fact they need. The common facts building_height_mm, wall_height_mm, storeys, gfa_m2 and car_spaces are shared by every pack.
YAML
The same fields:
id: seaview-estate
name: Seaview Estate design guidelines
version: "2026.1"
source_url: https://example.org/seaview-guidelines.pdf
rules:
- id: front-setback
title: House front setback
ref: "4.1"
each: dwellings
metric: front_setback_mm
op: ">="
limit: 6000
unit: mm
tolerance: 200
Quote operators (">=") and versions ("2026.1").
Tables: Excel, CSV and TSV
Most studios keep their standards in a spreadsheet, so a pack can be one: one rule per row under a header row.
The Excel template (plotlay-rule-pack-template.xlsx) has four sheets:
- Rules: the columns below, one rule per row, with a dropdown on each column that takes a set of values (Applies to, What's measured, Comparison, Unit, Confidence) and a note on every column saying what it takes.
- About the pack: the pack's details (name, id, kind, jurisdiction, version, dates, author, source), one per row: the field's name in column A, its value in column B.
- Instructions: how to fill it in, worked examples (a hallway width, a vanity height of 850 ± 20, a shower recess, a door clear width, a check by hand), and every column explained.
- Lists: the values the dropdowns offer, and every measure with what it is and its unit.
Plotlay reads the sheet named Rules (or, in another workbook, the first sheet with a header row it recognises) and the About the pack sheet. An exported pack is the same workbook, filled in.
The CSV template has the same columns and the same examples as rows. The pack's details go on # key: value lines above the header (# name: Seaview Studio standards, # version: 2); any other line starting with # is a note. A value that needs more than one line, or is a list or an object (params), is written as JSON on its line. The CSV is UTF-8 with a byte order mark, so Excel shows m² and ± correctly.
# name: Seaview Studio standards
# version: 1
# kind: template
Rule id,Rule,Applies to,Which ones,What’s measured,Comparison,Limit,Minimum,Maximum,Target,Plus or minus,Unit,Tolerance,Clause,Note
hall-width,Hallway clear width,rooms,room_type=hall,min_dim_mm,>=,1000,,,,,mm,10,2.1,Example figure: use your own.
vanity-height,Vanity top height,fitout,item=vanity,top_mm,target,,,,850,20,mm,,4.3,Example figure: use your own.
shower-recess,"Shower recess, shorter side",fitout,item=shower,depth_mm,,,900,,,,mm,,4.5,Example figure: use your own.
waterproofing,Waterproofing to the wet areas,rooms,,,check,,,,,,,,4.9,Check by hand: the membrane and its upturns.
The columns
| Column | Rule field | Also read as |
|---|---|---|
| Rule id | id |
id, code, key. Left blank, one is made from the rule's name. |
| Rule | title |
Title, Rule name, Name, Requirement, Standard (and Description or Item when no other column is the rule's name) |
| Applies to | each |
Each, Element, Category, Object. Singular or plural (room, rooms), and fit-out, fixtures or items for fitout. |
| Which ones | where |
Where, Filter, Only. field=value, several separated by ;, and a vertical bar between values for either (kind=door|window): room_type=bedroom; status=proposed. Or JSON. |
| What's measured | metric |
Metric, Measure, Measurement, Check type, Dimension. A measure's id (min_dim_mm), each.metric (rooms.min_dim_mm), or its name as the Lists sheet gives it (Narrowest width). Left without Applies to, a measure only one kind of element has (such as turning_circle_mm) says what it applies to. |
| Comparison | op |
Operator, Test, Compare. >= <= > < == != between in exists check, target, or words: at least, min, ≥ (all >=), at most, max, ≤ (all <=), range, one of, check by hand, manual. Blank: worked out from the figures given. |
| Limit | limit |
Value, Figure, Threshold, Required. A number; 2..10 with between; values separated by a vertical bar with in (R20|R30); true or false. A cell can carry its comparison and unit: >= 1.2 m, 900 to 1200 mm, 850 ± 20 mm. |
| Minimum, Maximum | op and limit |
Min, At least, Lower limit; Max, At most, Upper limit. A Minimum alone is >=, a Maximum alone <=, both a range (between). |
| Target, Plus or minus | op: between, limit, target |
Nominal, Design value; ±, +/-, Tolerance band, Deviation. 20, or +20/-10 when the two sides differ. With a Target and no Plus or minus column, a Tolerance column is read as the plus or minus. |
| Unit | unit |
Units, UoM. mm, cm, m, m² (m2, sqm), mm², cm², %, ° (deg), in, ft, ft² (sq ft), or none for a count. Lengths and areas in other units are converted to the pack's own (millimetres, square metres): 1.2 m becomes 1200 mm. A unit in brackets in a header (Minimum (m)) is the unit for that column's figures. Blank: the measure's own unit. |
| Tolerance | tolerance |
Tol, Allowance, Leeway |
| Warn within, Warn within % | warn_within, warn_within_pct |
Warn, Warning band |
| Clause | ref |
Ref, Section, Reference, Clause no, Table |
| Source, Source link | source, source_url |
Document; URL, Link |
| Note | note |
Notes, Comments, Remarks, Guidance |
| Confidence | confidence |
high or medium |
| Checked on | verified |
Verified, Date checked. A date, or false. |
| Limit from, Applies if, Sun, Envelope (advanced) | limit_from, applies_if, sun, envelope |
JSON, as in this guide. Limit from also takes a project fact's id alone: zoning_front_setback_mm. |
| Counting parts at least (mm), Shown limit, Needs review (advanced) | min_width_mm, threshold, needs_review |
Headers are matched without regard to case, spaces or punctuation. A column Plotlay doesn't know is left out, and the preview says so. A row with a name but no measure and no figure is read as a check by hand.
Figures from other places. A file whose columns are separated by semicolons or tabs, as Excel saves a CSV in much of Europe, is read as it is, with decimal commas (1,2 is 1.2; 1.000,5 is 1000.5). In a comma file, 1,200 and 12 500 are thousands. A table copied from Excel, Numbers or Word and pasted is tab separated, and Excel's "Unicode text" (UTF-16) reads too. Dates typed into Excel are read as dates (2026-11-02).
Problems are reported by row, in the file's own column names: Row 7: Unit: 'mm²' isn't a length; this check measures a length (Narrowest width). The app shows every rule and every problem before anything is added, and can import the rules without problems and leave the others out (the connector: preview: true, and skip_bad_rows: true). A figure under 20 with no unit on a length (1.2) is read as millimetres, with a warning that metres need m in Unit.
Not a table. Plotlay reads tables and pack files, not rules written as prose in a PDF or Word document. An AI agent connected to Plotlay can read such a document and build the pack (Design codes, Import a pack, Have an AI agent build it): every rule it enters is marked for review.
Exporting a pack
Every pack exports in Excel, CSV, JSON and YAML: from the Design codes panel (Export… beside a pack, or in its Rules), or the connector's export_rule_pack. Exported and imported again, a pack is the same, field for field, in every format (the tests check every built-in pack this way). What is left out is bookkeeping: who added each rule and when, and a project's history of versions.
A built-in code can't be changed, so it exports as your own copy: a template with its own id (nsw-housing-code-my-copy), named "(my copy)", with based_on naming the code and version it came from. Import it, change its figures, and every other project keeps the published code. A pack file that carries a built-in code's own id comes in the same way, as your copy.
Versions and updates
- A project copies the pack at its version when it is chosen. Checks use that copy.
- Importing the same id at the same version replaces it. A new version is only used when someone chooses it (the app asks; the connector takes
upgrade: true). The version used before is kept in the pack's history. - A pack saved to a library is never changed: a change is a new version.
- Every compliance report lists the packs and versions it used.
Rules an AI agent enters
An agent connected to Plotlay can build a pack from a document it has read (create_rule_pack, update_rule_pack, import_rules), start from a template (get_rule_pack_template), or export a pack to change (export_rule_pack). Each rule it enters is marked "needs review" until a person confirms it in the app (Design codes, Rules, Confirm). Until then, reports say: "Includes rules entered by an AI agent and not yet reviewed."
Good practice for authors
- Cite a clause in
refand a link insource_urlfor every rule. - Never guess a number. If a figure depends on something you can't settle, use
limit_fromwith a param, orop: "check"with the figures in the note. - Say in the note what the check simplifies (an average of neighbours' setbacks, a formula, an exception).
- Give each version a date, and say which amendment of the source it reflects (
instrument_version,effective), and when you last checked it (checked). - Mark each figure
verifiedwith the date you checked it. A figure you could not check isverified: false, with a note starting "Unverified". - Write a
description: what the pack covers, and what it leaves out (overlays, heritage, other zones).
Checking the built-in packs
Plotlay's own packs are kept as reviewed JSON in data/codepacks/ and built with node scripts/codepacks.mjs. node scripts/validate-packs.mjs checks every pack (it runs with the tests): each figure cited and verified, dates set, units matching what is measured, params declared with the options a rule names, template packs holding no figures of their own, and fixtures that pass and fail every measured rule. --urls also fetches every source link.