Covers the nationally described space standard for new homes in England: minimum gross internal area by bedrooms, bed spaces and storeys, bedroom areas and widths, ceiling height and built-in storage. It applies only where the local plan adopts it, or to new homes made under permitted development. Does not cover wheelchair housing (Part M Category 3), the London Plan or other local standards, room layouts or building regulations.
Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.
The instrument
Technical housing standards: nationally described space standard (DCLG, March 2015), with the notes added 19 May 2016
As published on gov.uk 27 March 2015 with the notes dated 19 May 2016 (seen 2026-10-14; no later change). Applied through local plan policy (Planning Practice Guidance: Housing: optional technical standards) and, for new homes made under permitted development, by article 3(9A) and (9B) of the GPDO 2015. Source: gov.uk: Technical housing standards, nationally described space standard; GPDO 2015 article 3(9A).
What it checks
Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.
| Rule | Clause |
|---|---|
| Minimum gross internal area | NDSS para 10(a), Table 1 |
| Every bedroom at least 7.5 m² | NDSS para 10(c) |
| Every bedroom at least 2.15 m wide | NDSS para 10(c), (h) |
| Main double bedroom at least 11.5 m² | NDSS para 10(b), (d) |
| Main double bedroom at least 2.75 m wide | NDSS para 10(e) |
| Other double or twin bedrooms | NDSS para 10(d), (e) |
| Ceiling height 2.3 m | NDSS para 10(i) |
| Built-in storage | NDSS para 10(a), (h), Table 1 |
| The space standard applies to this home | PPG Housing: optional technical standards; GPDO 2015 art 3(9A), (9B) |