Covers the nationally described space standard for new homes in England: minimum gross internal area by bedrooms, bed spaces and storeys, bedroom areas and widths, ceiling height and built-in storage. It applies only where the local plan adopts it, or to new homes made under permitted development. Does not cover wheelchair housing (Part M Category 3), the London Plan or other local standards, room layouts or building regulations.

9rules checked on the drawing
2026.10.1pack version, checked 14 October 2026
27 March 2015instrument in effect from

Reference only. Rules are simplified from published sources and may be out of date or incomplete. Verify with the current code and your council, certifier or relevant authority before relying on them.

The instrument

Technical housing standards: nationally described space standard (DCLG, March 2015), with the notes added 19 May 2016

As published on gov.uk 27 March 2015 with the notes dated 19 May 2016 (seen 2026-10-14; no later change). Applied through local plan policy (Planning Practice Guidance: Housing: optional technical standards) and, for new homes made under permitted development, by article 3(9A) and (9B) of the GPDO 2015. Source: gov.uk: Technical housing standards, nationally described space standard; GPDO 2015 article 3(9A).

What it checks

Each rule names its clause, linked to the published text. Plotlay measures the drawing (rooms, walls, openings, the boundary and the site), uses the facts you enter about the site, and marks each rule pass, fail or check by hand.

RuleClause
Minimum gross internal areaNDSS para 10(a), Table 1
Every bedroom at least 7.5 m²NDSS para 10(c)
Every bedroom at least 2.15 m wideNDSS para 10(c), (h)
Main double bedroom at least 11.5 m²NDSS para 10(b), (d)
Main double bedroom at least 2.75 m wideNDSS para 10(e)
Other double or twin bedroomsNDSS para 10(d), (e)
Ceiling height 2.3 mNDSS para 10(i)
Built-in storageNDSS para 10(a), (h), Table 1
The space standard applies to this homePPG Housing: optional technical standards; GPDO 2015 art 3(9A), (9B)

What it does not cover

Reference only. Indicative only: the space standard is optional and applies only where your local planning authority has adopted it in its local plan, or to a new home created under permitted development. Plotlay uses the gross floor area you enter as the gross internal area and checks rooms as drawn; check the measurement rules (headroom, storage and stairs) by hand and confirm with your planning authority.