Learn · Designers and builders · Lesson 43 of 58
Draw ducts, pipes and cable trays as systems
You willRun a supply air duct from a ducted unit to two outlets and a sewer drain from a toilet, and read the schedule of lengths and fittings.
Time8 min
Why it mattersServices drawn as joined runs tell you what each system serves, how much duct and pipe it needs and where a run is left open.
You needThe Standard or Pro level (the level chip in the top bar).
Try it in Plotlay → Opens an example project with this lesson beside it. Nothing to install.
Steps
- Open the Library, choose Energy & services, then Ducts, pipes and trays. Pick Supply air duct, rectangular.
- Set its Width, Depth and the Height of its centre above the floor (3.0 puts it in the roof space), then click along its route and double-click to finish.
- Pick Supply air duct, flexible and start it on the first duct. Where the two meet Plotlay works out a tee; where a run turns, a bend; where the size changes, a reducer.
- End a run on a ceiling outlet or start one on the ducted unit: a run that ends at a fixture joins its connection point.
- Pick Sewer drain (with a fall) and draw from the toilet out past the wall. It falls at 1 in 60 from its first point; leave its far end open, that is the outlet.
- Press Ctrl or Cmd + K and choose Building services: systems and schedule to see each system, what it serves, its open ends, lengths by size and the fittings count.
Tips
- Click a run to change its system, size, height, fall, insulation and hangers in the panel. The panel says how long it is and what it joins.
- A riser (Library: Duct riser, Pipe riser or stack, Cable riser) joins the runs that reach it on the floor below and the floor above.
- Plan sheets draw a run as one line at 1:100 and to its true width at 1:50, with its system letters and size. The IFC export carries segments, fittings, ports and systems.
- Your AI agent does the same through the connector: add_service_run, add_service_item, set_service_item and list_services.
Common mistakes
- An open end where two runs should meet: one stops short of the other, or sits at a different height. Give both the same height, or start the second on the first.
- A run joined to the wrong system: runs of different systems that meet are flagged in the system browser. Move one in its panel.
- A drain that does not join the main: a branch may arrive up to 300 mm above the main and still join; more than that, lower its start height.
Words in this lesson
- IFC
- The open file format BIM programs swap. Every thing in it has a class (IfcWall, IfcDoor, IfcSpace for a room), property sets and a GlobalId. Plotlay reads IFC2X3, IFC4 and IFC4X3 and writes IFC4.
- Library
- Furniture, fittings and equipment at real sizes, by category and subcategory: kitchen, bathroom, furniture, lighting, power, heating, stairs, outdoor, site, commercial, vehicles, plants. Search in your own words (GPO, countertop), filter, and star favourites.
- Schedule
- A table drawn from the plan: rooms and finishes, doors, windows, plants or materials. It updates as the plan changes and downloads as CSV.
- Connector (MCP)
- The way Claude and other AI agents work in your Plotlay projects as you, through the Model Context Protocol at app.plotlay.io/mcp.
Related lessons
Size ducts, pipes and drains with the sums shownWork out duct sizes from the air each outlet takes, check a drain against its fall, and download the calculation report.8 minCheck services against structure for clashesFind where a duct runs through a beam or a wall, give each clash a status, resolve one with a sleeve and send the rest as BCF.8 minExport an IFC model others can openSend the whole building as one IFC4 file, on its map grid, with ids that stay the same each time, and know what it holds.4 min
Steps checked in the app on 15 November 2026.