Size ducts, pipes and drains with the sums shown

You willWork out duct sizes from the air each outlet takes, check a drain against its fall, and download the calculation report.
Time8 min
Why it mattersA first sizing tells you whether the ducts fit the ceiling space and the drain has enough fall, before the engineer or plumber checks it.
You needDucts or pipes drawn as runs (the lesson before this one).

Try it in Plotlay → Opens an example project with this lesson beside it. Nothing to install.

Steps

  1. Press Ctrl or Cmd + K and choose Size building services. It opens on Ducts.
  2. Type the Air flow at each terminal in litres a second. One left blank is taken as 60 L/s and marked assumed.
  3. Set the Friction rate (0.8 Pa/m to start), the Velocity limit and the Deepest duct your ceiling space allows. The table shows each run with its flow, size, velocity and pressure drop.
  4. Open The sums to read how each size was reached, with the numbers put in. Method and sources names the method.
  5. Choose Apply sizes to change the runs. Undo puts them back.
  6. Open Drains: each run shows the fixtures it takes, the design flow, what the pipe carries at its fall and the size. A fall under the least you entered is flagged.
  7. Choose Report (Word) or Report (PDF) for the inputs, sums, results and sources of every calculation.

Tips

  • Water pipes: flow rates of the fixtures served with a simultaneity factor, then the smallest size under your velocity limit.
  • Tables from AS/NZS 3500 are under copyright and are not built in. Pick the loading unit or fixture unit method and type your own table to size by them.
  • Cable trays: list each tray’s cables as count x diameter to see its fill against your limit. Switchboard load adds the items nearest each board.
  • A size you have fixed stays: your AI agent can lock a run with set_service_item, and size with size_ducts, size_pipes and size_drains.

Common mistakes

  • Treating the result as a design: it is a design aid. A qualified engineer or licensed trade checks it against the current standards and the site.
  • "Nothing this system joins is where it starts": end a run at the unit, the heater or the water supply, or pick the run it starts with.
  • A run sized for more than it needs: a branch leaves part way along it. Draw it as two runs to step the size down after the branch.
Check yourself

A terminal has no air flow typed in. What does the duct sizing do?